Skip to main content
North-Central Zone · VA North-Central ENERGY STAR Zone · IECC 4 · Wildfire Safety (#1 = lowest risk): #1,342 of 3,143 (tied with 2 others at 42.7 pts) · top 42.8%

Staunton city, Virginia Climate Zone, Housing Age & Hazard Profile

USFS April 2026 wildfire analytics across Staunton city, Virginia classify 2,354 buildings in direct exposure (22.1% vs 58.8% statewide) and 4,402 in indirect smoke/ember buffers, alongside ENERGY STAR North-Central envelope targets across 2 postal ZIP areas and 26,361 residents under 2021 IECC with amendments. Nationally, the county ranks #1,342 of 3,143 by lowest risk and records 1 OpenFEMA declaration.

Size Attic Insulation
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
ENERGY STAR v7 Zone
North-Central
Window U / SHGC
<= 0.25 | <= 0.40
Attic Insulation Target
R60 (R49 w/ existing)
Pre-1980 Lead Risk
76.1%

What window, insulation, and wildfire benchmarks apply in Staunton city?

Staunton city enforces North-Central EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.25 U-Factor, <= 0.40 SHGC) alongside R60 (R49 w/ existing) attic and R5 to R10 insulative sheathing wall insulation goals.

National County Wildfire Safety Position

Staunton city Wildfire Safety RankWildfire Risk 42.7 pct stands at rank #1,342 of 3,143, outperforming 57.3% of peers.Wildfire Risk 42.7 pctRank #1,342 of 3,143 (57.3% standing)Higher ExposureNational/Cohort Median (50th)Lowest Risk (#1)

Wildfire Risk 42.7 pct (#1,342 of 3,143) positioned along the peer percentile scale.

Building Parameter / Metric Staunton city Requirement or Value Comparison / Notes
ENERGY STAR v7.0 Window Zone North-Central U-Factor <= 0.25 · SHGC <= 0.40
Recommended Attic & Wall R-Value Attic R60 (R49 w/ existing) · Wall R5 to R10 insulative sheathing ENERGY STAR Seal & Insulate Tier
USFS Indexed Buildings & Share 10,645 structures (2 ZIPs) 0.29% of Virginia building inventory
Direct Wildfire Flame Exposure 2,354 buildings (22.1%) State average: 58.8%
Indirect Smoke / Ember Zone 4,402 buildings (41.3%) State average: 18.9%
Minimal Wildfire Exposure 3,889 buildings (36.5%) State average: 22.4%
OpenFEMA Declarations (2020–2026) 1 event (-1.0 vs VA med) Winter Storm: 1
IECC & Building America Climate Zone 4 (Mixed-Humid) Moisture regime: A
ACS 2023 Housing Age & Lead RRP Risk 12,352 units (76.1% pre-1980) 44.1% built pre-1960 · 21.0% age 65+
ACS 2023 Primary Heating Fuel & Value 48.2% gas / 46.9% electric Median home value $239,300
FEMA NRI Multi-Hazard & Sub-Grade Very Low NRI (Wind 36.2, Hail 23.1) EPA Radon Zone 1 · Water table 1.8 ft

USFS spatial mapping places 6,756 structures in combined direct and indirect wildfire zones, leaving 3,889 minimal-risk structures (36.5% vs 22.4% Virginia average). Burn-probability standing ranks #1,433 of 3,143 U.S. counties (#1 = lowest burn prob.; 4.4 pts lower burn probability than the 50.0 pts median).

Regional storm and fire logs record 1 FEMA event since 2020 (Winter Storm: 1), shifting -1.0 relative to Virginia's 2 median county frequency. Specifying non-combustible siding and ember-resistant soffit vents pairs directly with ENERGY STAR North-Central glazing.

Natural gas heats 48.2% of occupied Staunton city homes compared with 46.9% electric heat, making winter conductive U-Factor control in IECC Zone 4 (Mixed-Humid) a primary heating-bill lever. With 76.1% of 12,352 homes built prior to 1980 (44.1% pre-1960), paid window or siding disturbance in Staunton city triggers strict EPA Lead-Safe RRP containment rules across most neighborhoods.

Building science context in IECC Zone 4 (Mixed-Humid, A) pairs EPA Radon Zone 1 with crawlspace/slab vapor barriers. FEMA NRI hurricane score reaches 62.3 and wind sits at 36.2, underscoring impact-rated glazing, ring-shank siding nails, and 6-in continuous gutters.

What construction trade wage benchmarks apply near Staunton city?

Hourly labor figures for window, insulation, and framing crews in Staunton city come from May 2025 Bureau of Labor Statistics wage reports for Virginia.

Glazier Hourly Median (BLS May 2025)

$28.49/hr in Virginia (U.S. median $27.44/hr).

Insulation Installer Median (BLS May 2025)

$21.54/hr in Virginia (U.S. median $23.62/hr).

How do nearby counties compare on wildfire safety and ENERGY STAR zones?

Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Virginia subdivisions.

Nearby U.S. County Distance ENERGY STAR Zone National Wildfire Rank Risk vs. Staunton city
Augusta County, VA 4.4 mi North-Central #1,847 of 3,143 +16.1 pts higher risk
Waynesboro city, VA 10.7 mi North-Central #1,502 of 3,143 +5.1 pts higher risk
Harrisonburg city, VA 21.8 mi North-Central #1,169 of 3,143 -5.5 pts lower risk
Rockingham County, VA 26.0 mi North-Central #1,807 of 3,143 +14.8 pts higher risk
Nelson County, VA 27.3 mi North-Central #1,725 of 3,143 +12.2 pts higher risk

What code, wildfire, and Lead RRP questions affect Staunton city?

County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for Staunton city appear below.

What share of buildings in Staunton city, VA face direct or indirect wildfire risk?

USDA Forest Service inventory maps 10,645 buildings in Staunton city: 2,354 face direct exposure (22.1% vs. 58.8% in Virginia), 4,402 face ember drift, and 3,889 remain minimal risk.

How does Staunton city compare nationally and statewide for wildfire safety?

With top 42.8% national standing at #1,342 of 3,143 (tied with 2 others at 42.7 pts), Staunton city ranks #84 among 133 Virginia counties (#1 = lowest risk) and holds #1,433 of 3,143 (tied with 2 others at 45.6 pts) for burn probability.

What window air-leakage and U-Factor specs fit Staunton city?

Across 2 ZIP areas in Staunton city, ENERGY STAR v7.0 sets North-Central thresholds at <= 0.25 U-Factor and <= 0.40 SHGC, paired with 0.3 cfm/ft2 maximum air leakage.

How do you size attic cellulose bags for a 1,500 sq ft home in Staunton city?

ENERGY STAR Seal and Insulate specifies R60 (R49 w/ existing) for Staunton city attics. Multiply square footage divided by 29 sq ft per R-38 bag by Target_R / 38, and obtain a signed FTC 16 CFR 460.17 receipt.

How does Staunton city's FEMA storm frequency compare to the VA county median?

FEMA records 1 storm or fire declaration in Staunton city since 2020 (Winter Storm: 1; -1.0 vs VA med). Pair continuous drainage barriers with corrosion-resistant fasteners.

Does Staunton city's 63.5% exposure share restrict siding materials?

Homeowners near Staunton city's 2,354 direct-exposure buildings should skip standard vinyl and wood shingle siding in favor of non-combustible fiber cement installed with 6-in ground clearance and kickout flashing.

What BLS May 2025 hourly wage benchmarks apply to exterior crews in Staunton city?

ACS 2023 shows 76.1% of 12,352 homes in Staunton city were built before 1980, elevating pre-1978 EPA Lead RRP checks alongside Virginia's $28.49/hr BLS glazier median (vs. $27.44/hr U.S.).

What IECC climate zone, radon tier, and Lead RRP authority govern Staunton city?

Operating in IECC Zone 4 (EPA Radon Zone 1), paid exterior contractors disturbing painted surfaces in pre-1978 Staunton city homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.

Which official federal and state sources back this page?

Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for Staunton city resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.

  1. Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
  2. ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
  3. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  4. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  5. State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
  6. DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
  7. U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
  8. FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
  9. U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
  10. USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
  11. OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
  12. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  13. U.S. Census Bureau 2024 Gazetteer & Vintage 2024 Population Estimates (States, Counties & Places) — U.S. Census Bureau, Vintage 2024 (checked 2026-11-23)
  14. Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros