Skip to main content
North-Central Zone · VA North-Central ENERGY STAR Zone · IECC 4 · Wildfire Safety (#1 = lowest risk): #1,502 of 3,143 (tied with 2 others at 47.8 pts) · top 47.9%

Waynesboro city, Virginia Climate Zone, Housing Age & Hazard Profile

USFS April 2026 wildfire analytics across Waynesboro city, Virginia classify 1,593 buildings in direct exposure (17.0% vs 58.8% statewide) and 5,104 in indirect smoke/ember buffers, alongside ENERGY STAR North-Central envelope targets across 1 postal ZIP areas and 23,498 residents under 2021 IECC with amendments. Nationally, the county ranks #1,502 of 3,143 by lowest risk and records 1 OpenFEMA declaration.

Size Attic Insulation
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
Wildfire-hardened residential wall with fiber-cement cladding, boxed metal eaves, and gravel clearance
ENERGY STAR v7 Zone
North-Central
Window U / SHGC
<= 0.25 | <= 0.40
Attic Insulation Target
R60 (R49 w/ existing)
Pre-1980 Lead Risk
61.8%

What window, insulation, and wildfire benchmarks apply in Waynesboro city?

Waynesboro city enforces North-Central EPA ENERGY STAR Version 7.0 window benchmarks (<= 0.25 U-Factor, <= 0.40 SHGC) alongside R60 (R49 w/ existing) attic and R5 to R10 insulative sheathing wall insulation goals.

National County Wildfire Safety Position

Waynesboro city Wildfire Safety RankWildfire Risk 47.8 pct stands at rank #1,502 of 3,143, outperforming 52.2% of peers.Wildfire Risk 47.8 pctRank #1,502 of 3,143 (52.2% standing)Higher ExposureNational/Cohort Median (50th)Lowest Risk (#1)

Wildfire Risk 47.8 pct (#1,502 of 3,143) positioned along the peer percentile scale.

Building Parameter / Metric Waynesboro city Requirement or Value Comparison / Notes
ENERGY STAR v7.0 Window Zone North-Central U-Factor <= 0.25 · SHGC <= 0.40
Recommended Attic & Wall R-Value Attic R60 (R49 w/ existing) · Wall R5 to R10 insulative sheathing ENERGY STAR Seal & Insulate Tier
USFS Indexed Buildings & Share 9,354 structures (1 ZIP) 0.26% of Virginia building inventory
Direct Wildfire Flame Exposure 1,593 buildings (17.0%) State average: 58.8%
Indirect Smoke / Ember Zone 5,104 buildings (54.6%) State average: 18.9%
Minimal Wildfire Exposure 2,657 buildings (28.4%) State average: 22.4%
OpenFEMA Declarations (2020–2026) 1 event (-1.0 vs VA med) Winter Storm: 1
IECC & Building America Climate Zone 4 (Mixed-Humid) Moisture regime: A
ACS 2023 Housing Age & Lead RRP Risk 10,395 units (61.8% pre-1980) 34.9% built pre-1960 · 17.7% age 65+
ACS 2023 Primary Heating Fuel & Value 48.7% gas / 46.3% electric Median home value $236,600
FEMA NRI Multi-Hazard & Sub-Grade Very Low NRI (Wind 28.5, Hail 19.2) EPA Radon Zone 1 · Water table 1.9 ft

USFS spatial mapping places 6,697 structures in combined direct and indirect wildfire zones, leaving 2,657 minimal-risk structures (28.4% vs 22.4% Virginia average). Burn-probability standing ranks #1,461 of 3,143 U.S. counties (#1 = lowest burn prob.; 3.5 pts lower burn probability than the 50.0 pts median).

Historical OpenFEMA records between 2020 and 2026 show 1 OpenFEMA declaration touching Waynesboro city, shifting -1.0 relative to Virginia's 2 median county frequency (Winter Storm: 1). Envelope upgrades balance North-Central window efficiency against Class A fire shutters or fiber-cement cladding.

Natural gas heats 48.7% of occupied Waynesboro city homes compared with 46.3% electric heat, making winter conductive U-Factor control in IECC Zone 4 (Mixed-Humid) a primary heating-bill lever. With 61.8% of 10,395 homes built prior to 1980 (34.9% pre-1960), paid window or siding disturbance in Waynesboro city triggers strict EPA Lead-Safe RRP containment rules across most neighborhoods.

Building science context in IECC Zone 4 (Mixed-Humid, A) pairs EPA Radon Zone 1 with crawlspace/slab vapor barriers. FEMA NRI hurricane score reaches 61.4 and wind sits at 28.5, underscoring impact-rated glazing, ring-shank siding nails, and 6-in continuous gutters.

What construction trade wage benchmarks apply near Waynesboro city?

Hourly labor figures for window, insulation, and framing crews in Waynesboro city come from May 2025 Bureau of Labor Statistics wage reports for Virginia.

Glazier Hourly Median (BLS May 2025)

$28.49/hr in Virginia (U.S. median $27.44/hr).

Insulation Installer Median (BLS May 2025)

$21.54/hr in Virginia (U.S. median $23.62/hr).

How do nearby counties compare on wildfire safety and ENERGY STAR zones?

Compare wildfire exposure percentages, pre-1980 housing shares, distance in miles, and ENERGY STAR zones across neighboring U.S. counties and sibling Virginia subdivisions.

Nearby U.S. County Distance ENERGY STAR Zone National Wildfire Rank Risk vs. Waynesboro city
Staunton city, VA 10.7 mi North-Central #1,342 of 3,143 -5.1 pts lower risk
Augusta County, VA 14.9 mi North-Central #1,847 of 3,143 +11.0 pts higher risk
Albemarle County, VA 19.2 mi North-Central #1,338 of 3,143 -5.2 pts lower risk
Nelson County, VA 19.2 mi North-Central #1,725 of 3,143 +7.1 pts higher risk
Charlottesville city, VA 22.7 mi North-Central #741 of 3,143 -24.2 pts lower risk

What code, wildfire, and Lead RRP questions affect Waynesboro city?

County-level compliance, pre-1980 ACS housing share, EPA radon zone, FEMA NRI wind hazard, and OpenFEMA storm history questions for Waynesboro city appear below.

Where does wildfire exposure concentrate across Waynesboro city's 9,354 buildings?

USDA Forest Service inventory maps 9,354 buildings in Waynesboro city: 1,593 face direct exposure (17.0% vs. 58.8% in Virginia), 5,104 face ember drift, and 2,657 remain minimal risk.

What is Waynesboro city's wildfire and burn-probability safety standing?

Statewide rankings put Waynesboro city at #90 of 133 Virginia subdivisions (#1 = lowest risk), while national wildfire rank sits at #1,502 of 3,143 (tied with 2 others at 47.8 pts) and burn probability stands at #1,461 of 3,143 (tied with 2 others at 46.5 pts).

How low must U-Factor and SHGC be for Waynesboro city windows?

Inspectors and buyers in Waynesboro city target North-Central ratings (<= 0.25 U-Factor; <= 0.40 SHGC; <= 0.3 cfm/ft2 air leakage) under EPA ENERGY STAR Version 7.0.

How much attic insulation does ENERGY STAR specify in Waynesboro city?

Using R60 (R49 w/ existing) targets in Waynesboro city, contractors blow settled cellulose per ASTM C177/C518 coverage charts (roughly 29 sq ft per bag at R-38) while keeping soffit air vents unobstructed.

What OpenFEMA disaster history affects exterior envelopes in Waynesboro city?

FEMA records 1 storm or fire declaration in Waynesboro city since 2020 (Winter Storm: 1; -1.0 vs VA med). Pair continuous drainage barriers with corrosion-resistant fasteners.

Which siding materials should homeowners avoid in high-exposure Waynesboro city areas?

Standard PVC vinyl siding deforms under radiant heat near wildland fuels (71.6% exposure in Waynesboro city). Homes abutting brush or trees should use non-combustible fiber cement or stucco with enclosed eaves.

What share of Waynesboro city, VA homes require Lead-Safe RRP window prep?

ACS 2023 shows 61.8% of 10,395 homes in Waynesboro city were built before 1980, elevating pre-1978 EPA Lead RRP checks alongside Virginia's $28.49/hr BLS glazier median (vs. $27.44/hr U.S.).

Does Waynesboro city require state-delegated or federal EPA Lead RRP verification?

Operating in IECC Zone 4 (EPA Radon Zone 1), paid exterior contractors disturbing painted surfaces in pre-1978 Waynesboro city homes must hold active federal U.S. EPA Lead-Safe RRP certification and provide the Renovate Right pamphlet.

Which official federal and state sources back this page?

Every building count, ACS 2023 housing metric, FEMA NRI wind score, EPA radon zone, and climate rule for Waynesboro city resolves directly to USFS, Census, FEMA, EPA, DOE, USDA, and BLS records.

  1. Wildfire Risk to Communities — State and County Building Exposure & Risk Ranks — USDA Forest Service, April 2026 Release (checked 2026-11-23)
  2. ENERGY STAR Climate Zone Assignments by ZIP Code and County (Version 7.0) — U.S. EPA ENERGY STAR, Version 7.0 (checked 2026-11-23)
  3. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  4. Recommended Home Insulation R-Values — Seal and Insulate With ENERGY STAR — U.S. EPA ENERGY STAR, Based on 2021 IECC Table R402.1.3 (checked 2026-11-23)
  5. State-Level Residential Building Energy Codes & Energy Use Index — U.S. DOE Building Energy Codes Program (BECP), September 2026 (checked 2026-11-23)
  6. DOE Building America & IECC Climate Zones by County (Moisture Regimes & Thermal Boundaries) — U.S. Department of Energy / PNNL, 2021/2024 IECC (checked 2026-11-25)
  7. U.S. Census American Community Survey (ACS) 5-Year Estimates — Housing Age, Heating Fuel, Income & Demographics — U.S. Census Bureau, 2019-2023 5-Year Estimates (checked 2026-11-25)
  8. FEMA National Risk Index (NRI) — County Multi-Hazard Risk, Wind, Hail, Hurricane, Wildfire & Flood Scores — Federal Emergency Management Agency (FEMA), National Risk Index County Release (checked 2026-11-25)
  9. U.S. EPA Map of Radon Zones & Indoor Radon Risk Percentiles — U.S. Environmental Protection Agency, EPA Radon Zone Reference (checked 2026-11-25)
  10. USDA NRCS Soil Survey Geographic Database (SSURGO) — Shallow Water Table & Drainage Depth — USDA Natural Resources Conservation Service, SSURGO County Extract (checked 2026-11-25)
  11. OpenFEMA Disaster Declarations Summaries v2 (2020-2026 Severe Storms, Hurricanes, Tornadoes & Fires) — Federal Emergency Management Agency (FEMA), v2 API (2020-2026) (checked 2026-11-23)
  12. Occupational Employment and Wage Statistics (OEWS) — State and Metropolitan Area Wages (SOC 47-2031, 47-2121, 47-2131) — U.S. Bureau of Labor Statistics, May 2025 (checked 2026-11-23)
  13. U.S. Census Bureau 2024 Gazetteer & Vintage 2024 Population Estimates (States, Counties & Places) — U.S. Census Bureau, Vintage 2024 (checked 2026-11-23)
  14. Lead Renovation, Repair and Painting (RRP) Program & EPA-Authorized State Programs — U.S. Environmental Protection Agency, 2026 (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros