Skip to main content
Door · Vinyl Frame NFRC ADC · Product Line ADC-K-33

Advanced Window Corp. — EU 76 Inswing/Outswing Door · Swinging Entry Door (Single)

EPA ENERGY STAR Version 7.0 certifies 720 variants inside Advanced Window Corp. EU 76 Inswing/Outswing Door, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.26 and SHGC 0.10 to 0.36. Qualifying for Northern, North-Central, South-Central, Southern, this Swinging Entry Door, Single family places #29 of 268 among 268 Door families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.16
SHGC Range
0.10-0.36
Certified Options
720
Category Standing
#29 of 268

How does Advanced Window Corp. EU 76 Inswing/Outswing Door compare thermally against Door peers?

Advanced Window Corp. EU 76 Inswing/Outswing Door achieves a 0.16 thermal floor across Door lines, placing #29 of 268 against the 0.21 category median.

Cohort Minimum U-Factor Distribution

Door U-Factor Distribution vs. EU 76 Inswing/Outswing DoorHistogram of 268 ENERGY STAR v7.0 Door lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing EU 76 Inswing/Outswing Door (U 0.16).28<=0.15650.16-0.18This model: U 0.16510.19-0.21710.22-0.24430.25-0.27100.28-0.3000.31-0.3500.36-0.420>0.42Category median min U: 0.21 (lower U = better thermal resistance)

Minimum U-Factor across 268 EPA-certified Door lines (category median: 0.21).

Thermal Standing & NFRC Anatomy

EU 76 Inswing/Outswing Door Cohort StandingMin U-Factor 0.16 stands at rank #29 of 268, outperforming 79.9% of peers.Min U-Factor 0.16Rank #29 of 268 (79.9% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across EU 76 Inswing/Outswing Door spans 720 NFRC test records (ADC), ranking #29 of 268 Door families (tied with 25 others at 0.16, more insulating than 79.9% of Door lines, top 20.1%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.10 to 0.36) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 720 combinations qualify in the Northern Zone alongside 498 Southern configurations matching hot-climate SHGC <= 0.23 caps.

Registry history records EPA FENSTAR licensing on 2018-06-13 and v7.0 data certification on 2024-04-01. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 720 certified glazing combinations for EU 76 Inswing/Outswing Door (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 720 packages (0 Most Eff.)
North-Central Certified <= 0.25 <= 0.40 720 packages (0 Most Eff.)
South-Central Certified <= 0.28 <= 0.23 498 packages (0 Most Eff.)
Southern Certified <= 0.32 <= 0.23 498 packages (0 Most Eff.)

Which competing Door series sit closest on U-Factor?

Inspect nearby Door competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Neuma Door — Neuma Hinged Door Vinyl 0.16 0.00 195
DRUTEX S.A. — IGLO Edge Slide Sliding Door Vinyl 0.16 0.16 137
OKNA Windows & Doors Mfg — 8800 Patio Door Vinyl 0.16 0.16 33
Seven D Windows and Door LLC — 7700/7800 Patio Door Vinyl 0.16 0.22 22
Euroline Windows Inc. — Energeto Neo-76 Inswing/Outswing Door Vinyl 0.16 0.11 1,761

What other certified series does Advanced Window Corp. produce?

Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. EU 76 Inswing/Outswing Door appear below.

How efficient is Advanced Window Corp. EU 76 Inswing/Outswing Door compared with peer Door models?

Across 720 tested NFRC glazing configurations, Advanced Window Corp. EU 76 Inswing/Outswing Door with Vinyl framing and Entry Door Single-Lite (EDSL) style reaches a 0.16 minimum U-Factor and 0.10-0.36 SHGC band. It places #29 among 268 Door series—top 20.1%.

Can homeowners install EU 76 Inswing/Outswing Door in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 720 EU 76 Inswing/Outswing Door packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

How does a 3x5 ft EU 76 Inswing/Outswing Door window perform under a 40 deg F temperature drop?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), EU 76 Inswing/Outswing Door at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Advanced Window Corp. EU 76 Inswing/Outswing Door and compare alternatives?

Skip EU 76 Inswing/Outswing Door if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on EU 76 Inswing/Outswing Door options exceeding U 0.22.

Is EU 76 Inswing/Outswing Door suitable for sunbelt cooling-dominated homes?

Warm-climate homeowners have 498 Southern-approved options within EU 76 Inswing/Outswing Door spanning SHGC down to 0.10. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside EU 76 Inswing/Outswing Door qualifies as Most Efficient?

EU 76 Inswing/Outswing Door holds zero Most Efficient entries across its 720 certified builds. Standard v7.0 compliance remains valid for local code permits, though utility rebates requiring Most Efficient tiers exclude it.

What federal compliance checks govern 2026 EU 76 Inswing/Outswing Door window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Advanced Window Corp. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do you cross-check NFRC ADC and product line ADC-K-33 on delivery?

Inspectors match the temporary NFRC sticker (U 0.16-0.26, SHGC 0.10-0.36) against permit drawings for line ADC-K-33. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. EU 76 Inswing/Outswing Door come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros