Skip to main content
Window · Vinyl Frame NFRC ADC · Product Line ADC-K-29 ENERGY STAR Most Efficient Eligible

Advanced Window Corp. — EU 76 Septem Fixed · Picture Window

With a minimum U-Factor of 0.13—-0.07 compared against the 0.20 Window median—Advanced Window Corp. EU 76 Septem Fixed spans 300 tested options across Northern, North-Central, South-Central, Southern up to 0.26 U-Factor. Carrying NFRC CPD code ADC, the Vinyl assembly includes 96 ENERGY STAR Most Efficient packages (32.0% of line) and offers SHGC packages between 0.15 and 0.51.

Min U-Factor
0.13
SHGC Range
0.15-0.51
Certified Options
300
Category Standing
#36 of 1,352

How does Advanced Window Corp. EU 76 Septem Fixed compare thermally against Window peers?

Advanced Window Corp. EU 76 Septem Fixed achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. EU 76 Septem FixedHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing EU 76 Septem Fixed (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

EU 76 Septem Fixed Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across EU 76 Septem Fixed spans 300 NFRC test records (ADC), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.06 against the Vinyl median (0.19).

Climate coverage for Advanced Window Corp. EU 76 Septem Fixed spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 96 configurations meet ENERGY STAR Most Efficient criteria while 171 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 78.0 BTU/hr (-40.9% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-06-13 and cert timestamp 2024-02-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 300 certified glazing combinations for EU 76 Septem Fixed (NFRC ADC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 171 packages (48 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 228 packages (60 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 141 packages (42 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 141 packages (66 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
ProVia LLC — Vinyl Casement Picture Window Vinyl 0.13 0.06 365
North Star Manufacturing (London) Ltd. — 1071 Fixed Vinyl 0.13 0.17 205
ProVia LLC — New Aspect/Endure Picture Window Vinyl 0.13 0.14 404
Slocomb Windows and Doors, Inc — 100 Series Picture Window Vinyl 0.13 0.15 158
Vytex Corporation — 3300 Fixed Vinyl 0.13 0.15 78

What other certified series does Advanced Window Corp. produce?

Compare other active Advanced Window Corp. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Advanced Window Corp. EU 76 Septem Fixed appear below.

How efficient is Advanced Window Corp. EU 76 Septem Fixed compared with peer Window models?

EPA ENERGY STAR v7.0 records 300 configurations for Advanced Window Corp. EU 76 Septem Fixed covering Northern, North-Central, South-Central, Southern, dropping down to U 0.13 versus a 0.20 Window median. Only 96 options earn Most Efficient status.

How does Advanced Window Corp. EU 76 Septem Fixed satisfy Version 7.0 Northern criteria?

Prescriptive Northern compliance covers 171 EU 76 Septem Fixed packages (U floor 0.13, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.

How much winter heat loss does EU 76 Septem Fixed conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), EU 76 Septem Fixed at U 0.13 conducts 78.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Which situations make EU 76 Septem Fixed the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on EU 76 Septem Fixed options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in EU 76 Septem Fixed?

Across Northern, North-Central, South-Central, Southern, 141 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Advanced Window Corp. EU 76 Septem Fixed, while total line SHGC reaches 0.51 in colder packages.

Which package tier in EU 76 Septem Fixed holds Most Efficient recognition?

Only 96 options out of 300 (32.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in Advanced Window Corp. EU 76 Septem Fixed, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to EU 76 Septem Fixed?

Any EU 76 Septem Fixed purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Advanced Window Corp. EU 76 Septem Fixed units match permits?

Verify NFRC ID ADC and series ADC-K-29 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Advanced Window Corp. EU 76 Septem Fixed come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros