Skip to main content
Window · Vinyl Frame NFRC SLC · Product Line SLC-K-8 ENERGY STAR Most Efficient Eligible

Slocomb Windows and Doors, Inc — 100 Series Picture Window · Picture Window

With a minimum U-Factor of 0.13—-0.07 compared against the 0.20 Window median—Slocomb Windows and Doors, Inc 100 Series Picture Window spans 158 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code SLC, the Vinyl assembly includes 73 ENERGY STAR Most Efficient packages (46.2% of line) and offers SHGC packages between 0.15 and 0.31.

Min U-Factor
0.13
SHGC Range
0.15-0.31
Certified Options
158
Category Standing
#36 of 1,352

How does Slocomb Windows and Doors, Inc 100 Series Picture Window compare thermally against Window peers?

Slocomb Windows and Doors, Inc 100 Series Picture Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 100 Series Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 100 Series Picture Window (U 0.13).249<=0.15This model: U 0.133140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

100 Series Picture Window Cohort StandingMin U-Factor 0.13 stands at rank #36 of 1,352, outperforming 94.7% of peers.Min U-Factor 0.13Rank #36 of 1,352 (94.7% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 100 Series Picture Window spans 158 NFRC test records (SLC), ranking #36 of 1,352 Window families (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%). Its 0.13 thermal floor compares at -0.06 against the Vinyl median (0.19).

Climate coverage for Slocomb Windows and Doors, Inc 100 Series Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 73 configurations meet ENERGY STAR Most Efficient criteria while 78 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors SLC to 2024-02-08 certification (FENSTAR issued 2023-03-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 78.0 BTU/hr conductive loss (-40.9% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 158 certified glazing combinations for 100 Series Picture Window (NFRC SLC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 78 packages (47 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 145 packages (64 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 98 packages (45 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 98 packages (54 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Slocomb Windows and Doors, Inc produce?

Compare other active Slocomb Windows and Doors, Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Slocomb Windows and Doors, Inc 100 Series Picture Window appear below.

How well does 100 Series Picture Window by Slocomb Windows and Doors, Inc insulate relative to Window benchmarks?

Slocomb Windows and Doors, Inc 100 Series Picture Window spans 158 certified configurations with U-Factors between 0.13 and 0.28 and SHGC values from 0.15 to 0.31. Ranked #36 of 1,352 Window families, it carries 73 Most Efficient options.

Which glazing options in Slocomb Windows and Doors, Inc 100 Series Picture Window meet Northern climate limits?

Yes. 78 packages in Slocomb Windows and Doors, Inc 100 Series Picture Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.28.

How much winter heat loss does 100 Series Picture Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.13 U-Factor yields 78.0 BTU/hr conductive transfer (-40.9% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying 100 Series Picture Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 100 Series Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many 100 Series Picture Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 98 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Slocomb Windows and Doors, Inc 100 Series Picture Window, while total line SHGC reaches 0.31 in colder packages.

Which package tier in 100 Series Picture Window holds Most Efficient recognition?

EPA lists 73 Most Efficient options (46.2% share) inside Slocomb Windows and Doors, Inc 100 Series Picture Window, out of 158 total Version 7.0 entries.

Do 2026 100 Series Picture Window installations qualify for IRS Section 25C tax credits?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

What permanent glass etch marks verify 100 Series Picture Window after sticker removal?

Verify NFRC ID SLC and series SLC-K-8 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Slocomb Windows and Doors, Inc 100 Series Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros