Slocomb Windows and Doors, Inc — 400/500 Series Double Slider · Double Slider
Positioning #250/1,352 in certified Window, Slocomb Windows and Doors, Inc 400/500 Series Double Slider pairs Vinyl frame construction with 212 glazing options rated between 0.13 and 0.45 SHGC across Northern, North-Central, South-Central, Southern. Across 8 certified Slocomb Windows and Doors, Inc product families, its thermal resistance spans 0.16 to 0.30 U-Factor and the line includes 86 ENERGY STAR Most Efficient packages (40.6% of line).
- Min U-Factor
- 0.16
- SHGC Range
- 0.13-0.45
- Certified Options
- 212
- Category Standing
- #250 of 1,352
How does Slocomb Windows and Doors, Inc 400/500 Series Double Slider compare thermally against Window peers?
Slocomb Windows and Doors, Inc 400/500 Series Double Slider achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Slocomb Windows and Doors, Inc 400/500 Series Double Slider standing at #250 of 1,352 certified Window product series, tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%. Comparing Vinyl profiles alone (median 0.19) shows -0.03 before selecting Low-E tiers.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 86 configurations meet ENERGY STAR Most Efficient criteria while 70 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2023-03-23 and v7.0 data certification on 2023-12-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 212 certified glazing combinations for 400/500 Series Double Slider (NFRC SLC) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 70 packages (24 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 128 packages (64 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 168 packages (64 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 192 packages (86 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Joyce Manufacturing Co. — Insulator/Heritage/Trinity Horizontal Slider | Vinyl | 0.16 | 0.14 | 216 |
| Advanced Window Corp. — 6300 Casement Picture Small | Vinyl | 0.16 | 0.17 | 201 |
| Mathews Brothers Company — Sanford Hills Double Hung | Vinyl | 0.16 | 0.18 | 227 |
| Mercury Excelum, Inc. — EOS\EOS+\ICON Casement | Vinyl | 0.16 | 0.16 | 190 |
| Vinylbilt Windows and Doors 2021 Inc — Platinum/Diamond Casement | Vinyl | 0.16 | 0.14 | 177 |
What other certified series does Slocomb Windows and Doors, Inc produce?
Compare other active Slocomb Windows and Doors, Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Slocomb Windows and Doors, Inc 400/500 Series Double Slider appear below.
Where does Slocomb Windows and Doors, Inc 400/500 Series Double Slider stand thermally among ENERGY STAR Window lines?
Across 212 tested NFRC glazing configurations, Slocomb Windows and Doors, Inc 400/500 Series Double Slider with Vinyl framing and Dual-Slide Horizontal (HSXX) style reaches a 0.16 minimum U-Factor and 0.13-0.45 SHGC band. It places #250 among 1,352 Window series—top 26.7%.
Is 400/500 Series Double Slider approved for Northern Zone heating climates?
Yes, 70 packages satisfy Northern ENERGY STAR Version 7.0 rules in 400/500 Series Double Slider. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft 400/500 Series Double Slider window perform under a 40 deg F temperature drop?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip Slocomb Windows and Doors, Inc 400/500 Series Double Slider and compare alternatives?
Skip 400/500 Series Double Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 400/500 Series Double Slider options exceeding U 0.22.
How many 400/500 Series Double Slider glazing packages pass Southern solar-heat rules?
Yes. 192 Southern-certified options inside Slocomb Windows and Doors, Inc 400/500 Series Double Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.45 SHGC on west-facing glass to avoid excess afternoon solar gain.
Which package tier in 400/500 Series Double Slider holds Most Efficient recognition?
Within 400/500 Series Double Slider, 40.6% (86 of 212) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What 2026 federal tax credit and Lead RRP rules apply to 400/500 Series Double Slider?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify 400/500 Series Double Slider glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.16-0.30, SHGC 0.13-0.45) against permit drawings for line SLC-K-4. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Slocomb Windows and Doors, Inc 400/500 Series Double Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)