Window · Vinyl Frame NFRC MBC · Product Line MBC-M-55 ENERGY STAR Most Efficient Eligible

Mathews Brothers Company — Sanford Hills Double Hung · Double Hung

EPA ENERGY STAR Version 7.0 certifies 227 variants inside Mathews Brothers Company Sanford Hills Double Hung, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.26 and SHGC 0.18 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Double Hung family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.16
SHGC Range
0.18-0.46
Certified Options
227
Category Standing
#250 of 1,352

How does Mathews Brothers Company Sanford Hills Double Hung compare thermally against Window peers?

Mathews Brothers Company Sanford Hills Double Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Sanford Hills Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Sanford Hills Double Hung (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Sanford Hills Double Hung Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 9 certified Mathews Brothers Company series, this Double Hung offers a 0.10 U-Factor adjustment span between 0.26 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).

Mapping NFRC SHGC values (0.18 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 84 configurations meet ENERGY STAR Most Efficient criteria while 167 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-06 and cert timestamp 2024-02-20.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 227 certified glazing combinations for Sanford Hills Double Hung (NFRC MBC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 167 packages (80 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 179 packages (78 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 105 packages (57 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 105 packages (57 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Mathews Brothers Company produce?

Compare other active Mathews Brothers Company certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Mathews Brothers Company Sanford Hills Double Hung appear below.

How efficient is Mathews Brothers Company Sanford Hills Double Hung compared with peer Window models?

EPA ENERGY STAR v7.0 records 227 configurations for Mathews Brothers Company Sanford Hills Double Hung covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 84 options earn Most Efficient status.

Is Sanford Hills Double Hung approved for Northern Zone heating climates?

Yes. 167 packages in Mathews Brothers Company Sanford Hills Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.

How do you calculate winter heat conduction for Mathews Brothers Company Sanford Hills Double Hung?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Mathews Brothers Company Sanford Hills Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Sanford Hills Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

How many Sanford Hills Double Hung glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 105 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Mathews Brothers Company Sanford Hills Double Hung, while total line SHGC reaches 0.46 in colder packages.

What glazing share inside Sanford Hills Double Hung qualifies as Most Efficient?

EPA lists 84 Most Efficient options (37.0% share) inside Mathews Brothers Company Sanford Hills Double Hung, out of 227 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Mathews Brothers Company Sanford Hills Double Hung in 2026?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Mathews Brothers Company upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

Where are NFRC and IGCC identification marks located on Sanford Hills Double Hung?

Confirm both the paper NFRC label and permanent corner glass etch match line MBC-M-55 and NFRC ID MBC before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Mathews Brothers Company Sanford Hills Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros