Window · Vinyl Frame NFRC VYW · Product Line VYW-A-47 ENERGY STAR Most Efficient Eligible

Vytex Corporation — 6000 Potomac Series Horizontal Slider · Double Slider

Across 18 Vytex Corporation certified families, 6000 Potomac Series Horizontal Slider supplies 248 Double Slider configurations starting at 0.16 U-Factor and 0.12 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.30 U-Factor and 0.26 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.12-0.26
Certified Options
248
Category Standing
#250 of 1,352

How does Vytex Corporation 6000 Potomac Series Horizontal Slider compare thermally against Window peers?

Vytex Corporation 6000 Potomac Series Horizontal Slider achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 6000 Potomac Series Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 6000 Potomac Series Horizontal Slider (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

6000 Potomac Series Horizontal Slider Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across 6000 Potomac Series Horizontal Slider spans 248 NFRC test records (VYW), ranking #250 of 1,352 Window families (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 44 configurations meet ENERGY STAR Most Efficient criteria while 44 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2024-03-05. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 248 certified glazing combinations for 6000 Potomac Series Horizontal Slider (NFRC VYW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 44 packages (8 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 88 packages (17 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 186 packages (17 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 236 packages (44 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vytex Corporation produce?

Compare other active Vytex Corporation certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vytex Corporation 6000 Potomac Series Horizontal Slider appear below.

Where does Vytex Corporation 6000 Potomac Series Horizontal Slider stand thermally among ENERGY STAR Window lines?

Vytex Corporation 6000 Potomac Series Horizontal Slider spans 248 certified configurations with U-Factors between 0.16 and 0.30 and SHGC values from 0.12 to 0.26. Ranked #250 of 1,352 Window families, it carries 44 Most Efficient options.

Does Vytex Corporation 6000 Potomac Series Horizontal Slider qualify for the ENERGY STAR Northern Zone?

Vytex Corporation 6000 Potomac Series Horizontal Slider supplies 44 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.30, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Vytex Corporation 6000 Potomac Series Horizontal Slider?

At U 0.16, a standard 3x5 ft (15 sq ft) 6000 Potomac Series Horizontal Slider opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

Who should NOT choose Vytex Corporation 6000 Potomac Series Horizontal Slider for a residential project?

Do not specify 6000 Potomac Series Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 6000 Potomac Series Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install Vytex Corporation 6000 Potomac Series Horizontal Slider in Southern or South-Central zones?

Yes. 236 Southern-certified options inside Vytex Corporation 6000 Potomac Series Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.26 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside 6000 Potomac Series Horizontal Slider qualifies as Most Efficient?

No. Exactly 44 of 248 configurations (17.7%) earn ENERGY STAR Most Efficient status in 6000 Potomac Series Horizontal Slider; the remaining standard v7.0 options pass base zone limits only.

What federal compliance checks govern 2026 6000 Potomac Series Horizontal Slider window swaps?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 6000 Potomac Series Horizontal Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC VYW and product line VYW-A-47 on delivery?

Match the NFRC thermal sticker for code VYW and line VYW-A-47 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vytex Corporation 6000 Potomac Series Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros