Skip to main content
Window · Vinyl Frame NFRC MBC · Product Line MBC-M-57 ENERGY STAR Most Efficient Eligible

Mathews Brothers Company — Sanford Hills Bendable Picture Window · Picture Window

Mathews Brothers Company Sanford Hills Bendable Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.16 across 81 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.23 to 0.51.

Min U-Factor
0.16
SHGC Range
0.23-0.51
Certified Options
81
Category Standing
#250 of 1,352

How does Mathews Brothers Company Sanford Hills Bendable Picture Window compare thermally against Window peers?

Mathews Brothers Company Sanford Hills Bendable Picture Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Sanford Hills Bendable Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Sanford Hills Bendable Picture Window (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Sanford Hills Bendable Picture Window Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows Mathews Brothers Company Sanford Hills Bendable Picture Window standing at #250 of 1,352 certified Window product series, tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%. Comparing Vinyl profiles alone (median 0.19) shows -0.03 before selecting Low-E tiers.

Climate coverage for Mathews Brothers Company Sanford Hills Bendable Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 25 configurations meet ENERGY STAR Most Efficient criteria while 67 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-06 and v7.0 data certification on 2025-05-13. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 81 certified glazing combinations for Sanford Hills Bendable Picture Window (NFRC MBC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 67 packages (25 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 32 packages (12 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 8 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 8 packages (4 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Mathews Brothers Company produce?

Compare other active Mathews Brothers Company certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Mathews Brothers Company Sanford Hills Bendable Picture Window appear below.

Where does Mathews Brothers Company Sanford Hills Bendable Picture Window stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 81 configurations for Mathews Brothers Company Sanford Hills Bendable Picture Window covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 25 options earn Most Efficient status.

How does Mathews Brothers Company Sanford Hills Bendable Picture Window satisfy Version 7.0 Northern criteria?

Yes. 67 packages in Mathews Brothers Company Sanford Hills Bendable Picture Window clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.

How much winter heat loss does Sanford Hills Bendable Picture Window conduct across a 15 sq ft opening?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Who should NOT choose Mathews Brothers Company Sanford Hills Bendable Picture Window for a residential project?

Do not specify Sanford Hills Bendable Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on Sanford Hills Bendable Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is Sanford Hills Bendable Picture Window suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 8 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Mathews Brothers Company Sanford Hills Bendable Picture Window, while total line SHGC reaches 0.51 in colder packages.

Does Sanford Hills Bendable Picture Window carry EPA Most Efficient certification across its lineup?

Within Sanford Hills Bendable Picture Window, 30.9% (25 of 81) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 Sanford Hills Bendable Picture Window installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Sanford Hills Bendable Picture Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do building inspectors verify Sanford Hills Bendable Picture Window glass specs on job sites?

Match the NFRC thermal sticker for code MBC and line MBC-M-57 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Mathews Brothers Company Sanford Hills Bendable Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros