Skip to main content
Window · Vinyl Frame NFRC MEX · Product Line MEX-M-24 ENERGY STAR Most Efficient Eligible

Mercury Excelum, Inc. — EOS\EOS+\ICON Casement · Casement Windows

Mercury Excelum, Inc. EOS\EOS+\ICON Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.16 across 190 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.33.

Min U-Factor
0.16
SHGC Range
0.16-0.33
Certified Options
190
Category Standing
#250 of 1,352

How does Mercury Excelum, Inc. EOS\EOS+\ICON Casement compare thermally against Window peers?

Mercury Excelum, Inc. EOS\EOS+\ICON Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. EOS\EOS+\ICON CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing EOS\EOS+\ICON Casement (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

EOS\EOS+\ICON Casement Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified Mercury Excelum, Inc. series, this Casement Windows offers a 0.13 U-Factor adjustment span between 0.29 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).

Climate coverage for Mercury Excelum, Inc. EOS\EOS+\ICON Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 80 configurations meet ENERGY STAR Most Efficient criteria while 68 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2025-08-07 and FENSTAR license 2018-09-05 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 190 certified glazing combinations for EOS\EOS+\ICON Casement (NFRC MEX) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 68 packages (40 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 160 packages (80 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 126 packages (72 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 138 packages (72 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Mercury Excelum, Inc. produce?

Compare other active Mercury Excelum, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Mercury Excelum, Inc. EOS\EOS+\ICON Casement appear below.

How well does EOS\EOS+\ICON Casement by Mercury Excelum, Inc. insulate relative to Window benchmarks?

EPA ENERGY STAR v7.0 records 190 configurations for Mercury Excelum, Inc. EOS\EOS+\ICON Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 80 options earn Most Efficient status.

Does Mercury Excelum, Inc. EOS\EOS+\ICON Casement qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 68 compliant Northern packages inside EOS\EOS+\ICON Casement, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.29 options.

How does a 3x5 ft EOS\EOS+\ICON Casement window perform under a 40 deg F temperature drop?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What are the practical limitations of specifying EOS\EOS+\ICON Casement?

Do not specify EOS\EOS+\ICON Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on EOS\EOS+\ICON Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is EOS\EOS+\ICON Casement suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 138 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Mercury Excelum, Inc. EOS\EOS+\ICON Casement, while total line SHGC reaches 0.33 in colder packages.

What glazing share inside EOS\EOS+\ICON Casement qualifies as Most Efficient?

No. Exactly 80 of 190 configurations (42.1%) earn ENERGY STAR Most Efficient status in EOS\EOS+\ICON Casement; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect EOS\EOS+\ICON Casement?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 EOS\EOS+\ICON Casement installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How do you cross-check NFRC MEX and product line MEX-M-24 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MEX and product line MEX-M-24, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Mercury Excelum, Inc. EOS\EOS+\ICON Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros