Skip to main content
Window · Vinyl Frame NFRC MEX · Product Line MEX-M-23 ENERGY STAR Most Efficient Eligible

Mercury Excelum, Inc. — EOS\EOS+\ICON Picture Window · Picture Window

Positioning #250/1,352 in certified Window, Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window pairs Vinyl frame construction with 64 glazing options rated between 0.18 and 0.26 SHGC across Northern, North-Central, South-Central, Southern. Across 6 certified Mercury Excelum, Inc. product families, its thermal resistance spans 0.16 to 0.32 U-Factor and the line includes 30 ENERGY STAR Most Efficient packages (46.9% of line).

Min U-Factor
0.16
SHGC Range
0.18-0.26
Certified Options
64
Category Standing
#250 of 1,352

How does Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window compare thermally against Window peers?

Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. EOS\EOS+\ICON Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing EOS\EOS+\ICON Picture Window (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

EOS\EOS+\ICON Picture Window Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified Mercury Excelum, Inc. series, this Picture Window offers a 0.16 U-Factor adjustment span between 0.32 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 30 configurations meet ENERGY STAR Most Efficient criteria while 32 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-05 licensing and 2025-08-07 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 64 certified glazing combinations for EOS\EOS+\ICON Picture Window (NFRC MEX) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 32 packages (19 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 36 packages (27 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 42 packages (20 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 55 packages (23 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
OKNA Windows & Doors Mfg — SL520/5520 Horizontal Slider Vinyl 0.16 0.19 60
Vector Windows — Envision Awning Vinyl 0.16 0.16 60
OKNA Windows & Doors Mfg — DH500/DH5500 Double Hung Vinyl 0.16 0.19 56
Vector Windows — Envision Casement Vinyl 0.16 0.16 73
Vector Windows — Envision Picture Window Vinyl 0.16 0.18 76

What other certified series does Mercury Excelum, Inc. produce?

Compare other active Mercury Excelum, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window appear below.

How efficient is Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window compared with peer Window models?

Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window spans 64 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.18 to 0.26. Ranked #250 of 1,352 Window families, it carries 30 Most Efficient options.

Is EOS\EOS+\ICON Picture Window approved for Northern Zone heating climates?

Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window supplies 32 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), EOS\EOS+\ICON Picture Window at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on EOS\EOS+\ICON Picture Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many EOS\EOS+\ICON Picture Window glazing packages pass Southern solar-heat rules?

Yes, EOS\EOS+\ICON Picture Window holds 55 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.18 SHGC in cooling climates.

What glazing share inside EOS\EOS+\ICON Picture Window qualifies as Most Efficient?

Within EOS\EOS+\ICON Picture Window, 46.9% (30 of 64) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What 2026 federal tax credit and Lead RRP rules apply to EOS\EOS+\ICON Picture Window?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 EOS\EOS+\ICON Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

Where are NFRC and IGCC identification marks located on EOS\EOS+\ICON Picture Window?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code MEX and product line MEX-M-23, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Mercury Excelum, Inc. EOS\EOS+\ICON Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros