Skip to main content
Window · Vinyl Frame NFRC OKW · Product Line OKW-K-18 ENERGY STAR Most Efficient Eligible

OKNA Windows & Doors Mfg — DH500/DH5500 Double Hung · Double Hung

Positioning #250/1,352 in certified Window, OKNA Windows & Doors Mfg DH500/DH5500 Double Hung pairs Vinyl frame construction with 56 glazing options rated between 0.19 and 0.22 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified OKNA Windows & Doors Mfg product families, its thermal resistance spans 0.16 to 0.29 U-Factor and the line includes 30 ENERGY STAR Most Efficient packages (53.6% of line).

Min U-Factor
0.16
SHGC Range
0.19-0.22
Certified Options
56
Category Standing
#250 of 1,352

How does OKNA Windows & Doors Mfg DH500/DH5500 Double Hung compare thermally against Window peers?

OKNA Windows & Doors Mfg DH500/DH5500 Double Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. DH500/DH5500 Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing DH500/DH5500 Double Hung (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

DH500/DH5500 Double Hung Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 21 certified OKNA Windows & Doors Mfg series, this Double Hung offers a 0.13 U-Factor adjustment span between 0.29 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).

Mapping NFRC SHGC values (0.19 to 0.22) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 30 configurations meet ENERGY STAR Most Efficient criteria while 32 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-05 licensing and 2024-05-16 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for DH500/DH5500 Double Hung (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 32 packages (26 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 32 packages (26 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 53 packages (26 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 56 packages (30 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vector Windows — Envision Awning Vinyl 0.16 0.16 60
Kohltech International, Ltd. — Select Awning Vinyl 0.16 0.17 50
Kohltech International, Ltd. — Select Casement Vinyl 0.16 0.17 50
Mercury Excelum, Inc. — EOS\EOS+\ICON Picture Window Vinyl 0.16 0.18 64
Vector Windows — Envision Casement Vinyl 0.16 0.16 73

What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg DH500/DH5500 Double Hung appear below.

What thermal performance numbers separate OKNA Windows & Doors Mfg DH500/DH5500 Double Hung from peers?

Built with Vinyl framing in Double-Hung (VSDH) style, OKNA Windows & Doors Mfg DH500/DH5500 Double Hung offers 56 Version 7.0 configurations from U 0.16 up to 0.29, posting -0.04 against the Window median of 0.20 with 30 Most Efficient picks.

Is DH500/DH5500 Double Hung approved for Northern Zone heating climates?

Yes. 32 packages in OKNA Windows & Doors Mfg DH500/DH5500 Double Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.29.

How do you calculate winter heat conduction for OKNA Windows & Doors Mfg DH500/DH5500 Double Hung?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on DH500/DH5500 Double Hung's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.29 transfer proportionally more energy.

Which situations make DH500/DH5500 Double Hung the wrong window or door choice?

Do not specify DH500/DH5500 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on DH500/DH5500 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install OKNA Windows & Doors Mfg DH500/DH5500 Double Hung in Southern or South-Central zones?

Yes, DH500/DH5500 Double Hung holds 56 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.19 SHGC in cooling climates.

Does DH500/DH5500 Double Hung carry EPA Most Efficient certification across its lineup?

Within DH500/DH5500 Double Hung, 53.6% (30 of 56) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 DH500/DH5500 Double Hung installations qualify for IRS Section 25C tax credits?

Any DH500/DH5500 Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify DH500/DH5500 Double Hung glass specs on job sites?

Verify NFRC ID OKW and series OKW-K-18 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg DH500/DH5500 Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros