Skip to main content
Window · Vinyl Frame NFRC OKW · Product Line OKW-K-25 ENERGY STAR Most Efficient Eligible

OKNA Windows & Doors Mfg — PW 710/4710 · Picture Window

With a minimum U-Factor of 0.14—-0.06 compared against the 0.20 Window median—OKNA Windows & Doors Mfg PW 710/4710 spans 96 tested options across Northern, North-Central, South-Central, Southern up to 0.28 U-Factor. Carrying NFRC CPD code OKW, the Vinyl assembly includes 48 ENERGY STAR Most Efficient packages (50.0% of line) and offers SHGC packages between 0.15 and 0.28.

Min U-Factor
0.14
SHGC Range
0.15-0.28
Certified Options
96
Category Standing
#72 of 1,352

How does OKNA Windows & Doors Mfg PW 710/4710 compare thermally against Window peers?

OKNA Windows & Doors Mfg PW 710/4710 achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. PW 710/4710Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing PW 710/4710 (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

PW 710/4710 Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places OKNA Windows & Doors Mfg PW 710/4710 at rank #72 of 1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.15-0.28 band.

Climate coverage for OKNA Windows & Doors Mfg PW 710/4710 spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 48 configurations meet ENERGY STAR Most Efficient criteria while 32 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2024-05-16. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.14 conducts 84.0 BTU/hr (-48.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 96 certified glazing combinations for PW 710/4710 (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 32 packages (24 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 77 packages (46 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 76 packages (42 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 76 packages (44 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg PW 710/4710 appear below.

How well does PW 710/4710 by OKNA Windows & Doors Mfg insulate relative to Window benchmarks?

Testing puts OKNA Windows & Doors Mfg PW 710/4710 at rank #72 of 1,352 Window entries with U 0.14 to 0.28 across 96 configurations. Solar heat gain ranges between 0.15 and 0.28 across Northern, North-Central, South-Central, Southern.

Does OKNA Windows & Doors Mfg PW 710/4710 qualify for the ENERGY STAR Northern Zone?

OKNA Windows & Doors Mfg PW 710/4710 supplies 32 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.

What conductive BTU/hr difference separates PW 710/4710 from the 0.22 Northern rule?

At U 0.14, a standard 3x5 ft (15 sq ft) PW 710/4710 opening transfers 84.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -48.0 BTU/hr difference.

When should a buyer skip OKNA Windows & Doors Mfg PW 710/4710 and compare alternatives?

Do not specify PW 710/4710 without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on PW 710/4710 options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many PW 710/4710 glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 76 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside OKNA Windows & Doors Mfg PW 710/4710, while total line SHGC reaches 0.28 in colder packages.

Are all 96 PW 710/4710 configurations ENERGY STAR Most Efficient?

EPA lists 48 Most Efficient options (50.0% share) inside OKNA Windows & Doors Mfg PW 710/4710, out of 96 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on OKNA Windows & Doors Mfg PW 710/4710 in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current PW 710/4710 retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify PW 710/4710 after sticker removal?

Inspectors match the temporary NFRC sticker (U 0.14-0.28, SHGC 0.15-0.28) against permit drawings for line OKW-K-25. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg PW 710/4710 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)