Skip to main content
Window · Vinyl Frame NFRC OKW · Product Line OKW-K-50 ENERGY STAR Most Efficient Eligible

OKNA Windows & Doors Mfg — 7560 Casement · Casement Windows

OKNA Windows & Doors Mfg 7560 Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.14 across 76 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #72 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.15 to 0.25.

Min U-Factor
0.14
SHGC Range
0.15-0.25
Certified Options
76
Category Standing
#72 of 1,352

How does OKNA Windows & Doors Mfg 7560 Casement compare thermally against Window peers?

OKNA Windows & Doors Mfg 7560 Casement achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7560 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 7560 Casement (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7560 Casement Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 21 certified OKNA Windows & Doors Mfg series, this Casement Windows offers a 0.12 U-Factor adjustment span between 0.26 entry options and 0.14 top-performing glazing. Category standing is #72/1,352 (tied with 63 others at 0.14, more insulating than 90.0% of Window lines, top 10.0%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 36 configurations meet ENERGY STAR Most Efficient criteria while 24 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.14 U-Factor yields 84.0 BTU/hr transfer (-48.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-05 licensing and 2024-04-24 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 76 certified glazing combinations for 7560 Casement (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 24 packages (8 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 74 packages (36 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 71 packages (36 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 71 packages (36 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg 7560 Casement appear below.

What U-Factor and SHGC range does OKNA Windows & Doors Mfg 7560 Casement achieve?

EPA ENERGY STAR v7.0 records 76 configurations for OKNA Windows & Doors Mfg 7560 Casement covering Northern, North-Central, South-Central, Southern, dropping down to U 0.14 versus a 0.20 Window median. Only 36 options earn Most Efficient status.

Is 7560 Casement approved for Northern Zone heating climates?

Yes, 24 packages satisfy Northern ENERGY STAR Version 7.0 rules in 7560 Casement. Pairing multi-pane insulation down to 0.14 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates 7560 Casement from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.14 U-Factor yields 84.0 BTU/hr conductive transfer (-36.4% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 7560 Casement the wrong window or door choice?

Do not specify 7560 Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 7560 Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install OKNA Windows & Doors Mfg 7560 Casement in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 71 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside OKNA Windows & Doors Mfg 7560 Casement, while total line SHGC reaches 0.25 in colder packages.

How many OKNA Windows & Doors Mfg 7560 Casement variants earn ENERGY STAR Most Efficient?

Only 36 options out of 76 (47.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in OKNA Windows & Doors Mfg 7560 Casement, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 7560 Casement window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 7560 Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on 7560 Casement?

Inspectors match the temporary NFRC sticker (U 0.14-0.26, SHGC 0.15-0.25) against permit drawings for line OKW-K-50. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg 7560 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)