Skip to main content
Window · Vinyl Frame NFRC VID · Product Line VID-K-67 ENERGY STAR Most Efficient Eligible

Vinyl Window Designs, Ltd. — 402 P3 Premium Low Fixed Picture Window · Picture Window

Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.14 across 48 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #72 of 1,352 in Window, its thermal floor is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.16 to 0.60.

Min U-Factor
0.14
SHGC Range
0.16-0.60
Certified Options
48
Category Standing
#72 of 1,352

How does Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window compare thermally against Window peers?

Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window achieves a 0.14 thermal floor across Window lines, placing #72 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 402 P3 Premium Low Fixed Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing 402 P3 Premium Low Fixed Picture Window (U 0.14).249<=0.15This model: U 0.143140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

402 P3 Premium Low Fixed Picture Window Cohort StandingMin U-Factor 0.14 stands at rank #72 of 1,352, outperforming 90.0% of peers.Min U-Factor 0.14Rank #72 of 1,352 (90.0% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 402 P3 Premium Low Fixed Picture Window is 0.06 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.14-0.26.

Regional qualification covers Northern, North-Central, South-Central, Southern. 28 configurations meet ENERGY STAR Most Efficient criteria while 43 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-08-23 and v7.0 data certification on 2024-07-02. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.14 conducts 84.0 BTU/hr (-48.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 48 certified glazing combinations for 402 P3 Premium Low Fixed Picture Window (NFRC VID) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 43 packages (20 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 30 packages (16 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 16 packages (8 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 16 packages (12 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.14 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vinyl Window Designs, Ltd. produce?

Compare other active Vinyl Window Designs, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window appear below.

What thermal performance numbers separate Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window from peers?

Across 48 tested NFRC glazing configurations, Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.14 minimum U-Factor and 0.16-0.60 SHGC band. It places #72 among 1,352 Window series—top 10.0%.

Does Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window qualify for the ENERGY STAR Northern Zone?

Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window supplies 43 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.26, so inspect the NFRC order sheet before purchase.

How much winter heat loss does 402 P3 Premium Low Fixed Picture Window conduct across a 15 sq ft opening?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 402 P3 Premium Low Fixed Picture Window at U 0.14 conducts 84.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window and compare alternatives?

Do not specify 402 P3 Premium Low Fixed Picture Window without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 402 P3 Premium Low Fixed Picture Window options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

What Southern ENERGY STAR v7.0 options exist in 402 P3 Premium Low Fixed Picture Window?

Yes, 402 P3 Premium Low Fixed Picture Window holds 16 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

What glazing share inside 402 P3 Premium Low Fixed Picture Window qualifies as Most Efficient?

No. Exactly 28 of 48 configurations (58.3%) earn ENERGY STAR Most Efficient status in 402 P3 Premium Low Fixed Picture Window; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect 402 P3 Premium Low Fixed Picture Window?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 402 P3 Premium Low Fixed Picture Window retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify 402 P3 Premium Low Fixed Picture Window after sticker removal?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code VID and product line VID-K-67, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinyl Window Designs, Ltd. 402 P3 Premium Low Fixed Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros