Skip to main content
Window · Vinyl Frame NFRC VID · Product Line VID-K-52 ENERGY STAR Most Efficient Eligible

Vinyl Window Designs, Ltd. — 800M Casement · Casement Windows

Vinyl Window Designs, Ltd. 800M Casement is a Casement Windows assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 41 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.12 to 0.41.

Min U-Factor
0.17
SHGC Range
0.12-0.41
Certified Options
41
Category Standing
#362 of 1,352

How does Vinyl Window Designs, Ltd. 800M Casement compare thermally against Window peers?

Vinyl Window Designs, Ltd. 800M Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 800M CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 800M Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

800M Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Vinyl Window Designs, Ltd. 800M Casement at rank #362 of 1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.12-0.41 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 18 configurations meet ENERGY STAR Most Efficient criteria while 21 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors VID to 2025-03-20 certification (FENSTAR issued 2018-08-23). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 41 certified glazing combinations for 800M Casement (NFRC VID) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 21 packages (6 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 37 packages (14 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 25 packages (10 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 25 packages (14 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Vinyl Window Designs, Ltd. produce?

Compare other active Vinyl Window Designs, Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Vinyl Window Designs, Ltd. 800M Casement appear below.

How efficient is Vinyl Window Designs, Ltd. 800M Casement compared with peer Window models?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Vinyl Window Designs, Ltd. 800M Casement offers 41 Version 7.0 configurations from U 0.17 up to 0.26, posting -0.03 against the Window median of 0.20 with 18 Most Efficient picks.

How does Vinyl Window Designs, Ltd. 800M Casement satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 21 compliant Northern packages inside 800M Casement, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.26 options.

How do you calculate winter heat conduction for Vinyl Window Designs, Ltd. 800M Casement?

Using NFRC VID U-Factor 0.17, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

Which situations make 800M Casement the wrong window or door choice?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on 800M Casement options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is 800M Casement suitable for sunbelt cooling-dominated homes?

Yes, 800M Casement holds 25 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.12 SHGC in cooling climates.

What glazing share inside 800M Casement qualifies as Most Efficient?

Not every package qualifies: 18 of 41 800M Casement glazing builds earn Most Efficient recognition (43.9%), while other variants sit on the standard Version 7.0 tier.

What 2026 federal tax credit and Lead RRP rules apply to 800M Casement?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 800M Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

Where are NFRC and IGCC identification marks located on 800M Casement?

Verify NFRC ID VID and series VID-K-52 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Vinyl Window Designs, Ltd. 800M Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros