Skip to main content
Window · Vinyl Frame NFRC NVP · Product Line NVP-K-15 ENERGY STAR Most Efficient Eligible

National Vinyl, LLC — TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider · Double Slider

National Vinyl, LLC engineered the TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider Double Slider line for Northern, North-Central, South-Central, Southern, certifying 51 glass-spacer combinations from 0.17 to 0.26 U-Factor and 0.22 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC NVP, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.22-0.49
Certified Options
51
Category Standing
#362 of 1,352

How does National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider compare thermally against Window peers?

National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified National Vinyl, LLC series, this Double Slider offers a 0.09 U-Factor adjustment span between 0.26 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 16 configurations meet ENERGY STAR Most Efficient criteria while 37 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-09-25.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 51 certified glazing combinations for TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider (NFRC NVP) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 37 packages (15 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 35 packages (14 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 11 packages (6 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 11 packages (7 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Seven D Windows and Door LLC — 7700/7800 Awning Vinyl 0.17 0.19 55
Seven D Windows and Door LLC — 7700/7800 Casement Vinyl 0.17 0.19 55
OKNA Windows & Doors Mfg — 400 Double Hung Vinyl 0.17 0.14 56
OKNA Windows & Doors Mfg — SL620-SL6620 Vinyl 0.17 0.17 56
Vinyl Window Designs, Ltd. — 800M Casement Vinyl 0.17 0.12 41

What other certified series does National Vinyl, LLC produce?

Compare other active National Vinyl, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider appear below.

How well does TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider by National Vinyl, LLC insulate relative to Window benchmarks?

Testing puts National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider at rank #362 of 1,352 Window entries with U 0.17 to 0.26 across 51 configurations. Solar heat gain ranges between 0.22 and 0.49 across Northern, North-Central, South-Central, Southern.

Which glazing options in National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider meet Northern climate limits?

Yes. 37 packages in National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.

How does a 3x5 ft TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider window perform under a 40 deg F temperature drop?

At U 0.17, a standard 3x5 ft (15 sq ft) TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

What are the practical limitations of specifying TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider?

Do not specify TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Can you install National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider in Southern or South-Central zones?

Yes. 11 Southern-certified options inside National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 51 TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider configurations ENERGY STAR Most Efficient?

Only 16 options out of 51 (31.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider in 2026?

Any TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider units match permits?

Verify NFRC ID NVP and series NVP-K-15 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros