National Vinyl, LLC — TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider · Double Slider
National Vinyl, LLC engineered the TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider Double Slider line for Northern, North-Central, South-Central, Southern, certifying 51 glass-spacer combinations from 0.17 to 0.26 U-Factor and 0.22 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC NVP, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.17
- SHGC Range
- 0.22-0.49
- Certified Options
- 51
- Category Standing
- #362 of 1,352
How does National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider compare thermally against Window peers?
National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 6 certified National Vinyl, LLC series, this Double Slider offers a 0.09 U-Factor adjustment span between 0.26 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 16 configurations meet ENERGY STAR Most Efficient criteria while 37 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2025-09-25.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 51 certified glazing combinations for TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider (NFRC NVP) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 37 packages (15 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 35 packages (14 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 11 packages (6 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 11 packages (7 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Seven D Windows and Door LLC — 7700/7800 Awning | Vinyl | 0.17 | 0.19 | 55 |
| Seven D Windows and Door LLC — 7700/7800 Casement | Vinyl | 0.17 | 0.19 | 55 |
| OKNA Windows & Doors Mfg — 400 Double Hung | Vinyl | 0.17 | 0.14 | 56 |
| OKNA Windows & Doors Mfg — SL620-SL6620 | Vinyl | 0.17 | 0.17 | 56 |
| Vinyl Window Designs, Ltd. — 800M Casement | Vinyl | 0.17 | 0.12 | 41 |
What other certified series does National Vinyl, LLC produce?
Compare other active National Vinyl, LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
TG/NW3/Destiny/DuraTrust/Clarion Picture Window
U-Factor 0.13–0.26 · 52 certified options.
TG/NW3/Destiny/Sentinel Deadlite
U-Factor 0.14–0.26 · 49 certified options.
TG/NW3/Destiny/Duratrust/Clarion/Sentinel Awning
U-Factor 0.18–0.30 · 73 certified options.
TG/NW3/Destiny/Duratrust/Clarion/Sentinel Casement
U-Factor 0.18–0.30 · 75 certified options.
EnduraView Sliding Patio Door
U-Factor 0.19–0.25 · 4 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider appear below.
How well does TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider by National Vinyl, LLC insulate relative to Window benchmarks?
Testing puts National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider at rank #362 of 1,352 Window entries with U 0.17 to 0.26 across 51 configurations. Solar heat gain ranges between 0.22 and 0.49 across Northern, North-Central, South-Central, Southern.
Which glazing options in National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider meet Northern climate limits?
Yes. 37 packages in National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.26.
How does a 3x5 ft TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider window perform under a 40 deg F temperature drop?
At U 0.17, a standard 3x5 ft (15 sq ft) TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.
What are the practical limitations of specifying TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider?
Do not specify TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Can you install National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider in Southern or South-Central zones?
Yes. 11 Southern-certified options inside National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.49 SHGC on west-facing glass to avoid excess afternoon solar gain.
Are all 51 TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider configurations ENERGY STAR Most Efficient?
Only 16 options out of 51 (31.4%) meet tighter Most Efficient U-Factor and SHGC thresholds in National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider, usually requiring triple-pane or upgraded Low-E coatings.
Can homeowners claim Form 5695 credits on National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider in 2026?
Any TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
How can homeowners confirm delivered National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider units match permits?
Verify NFRC ID NVP and series NVP-K-15 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for National Vinyl, LLC TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)