OKNA Windows & Doors Mfg — 400 Double Hung · Double Hung
With a minimum U-Factor of 0.17—-0.03 compared against the 0.20 Window median—OKNA Windows & Doors Mfg 400 Double Hung spans 56 tested options across Northern, North-Central, South-Central, Southern up to 0.30 U-Factor. Carrying NFRC CPD code OKW, the Vinyl assembly includes 25 ENERGY STAR Most Efficient packages (44.6% of line) and offers SHGC packages between 0.14 and 0.22.
- Min U-Factor
- 0.17
- SHGC Range
- 0.14-0.22
- Certified Options
- 56
- Category Standing
- #362 of 1,352
How does OKNA Windows & Doors Mfg 400 Double Hung compare thermally against Window peers?
OKNA Windows & Doors Mfg 400 Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows OKNA Windows & Doors Mfg 400 Double Hung standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 25 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-05-16 and FENSTAR license 2018-09-05 inside EPA Version 7.0 tables. Heat transfer computes to 102.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 56 certified glazing combinations for 400 Double Hung (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 14 packages (8 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 32 packages (16 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 46 packages (16 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 56 packages (25 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Seven D Windows and Door LLC — 7700/7800 Awning | Vinyl | 0.17 | 0.19 | 55 |
| Seven D Windows and Door LLC — 7700/7800 Casement | Vinyl | 0.17 | 0.19 | 55 |
| National Vinyl, LLC — TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider | Vinyl | 0.17 | 0.22 | 51 |
| Energex Window Alliance — Energex Picture Window | Vinyl | 0.17 | 0.14 | 66 |
| Vector Windows — Envision Glider | Vinyl | 0.17 | 0.17 | 67 |
What other certified series does OKNA Windows & Doors Mfg produce?
Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg 400 Double Hung appear below.
What U-Factor and SHGC range does OKNA Windows & Doors Mfg 400 Double Hung achieve?
OKNA Windows & Doors Mfg 400 Double Hung spans 56 certified configurations with U-Factors between 0.17 and 0.30 and SHGC values from 0.14 to 0.22. Ranked #362 of 1,352 Window families, it carries 25 Most Efficient options.
Which glazing options in OKNA Windows & Doors Mfg 400 Double Hung meet Northern climate limits?
OKNA Windows & Doors Mfg 400 Double Hung supplies 14 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.30, so inspect the NFRC order sheet before purchase.
How much winter heat loss does 400 Double Hung conduct across a 15 sq ft opening?
At U 0.17, a standard 3x5 ft (15 sq ft) 400 Double Hung opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.
What are the practical limitations of specifying 400 Double Hung?
Do not specify 400 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 400 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does 400 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?
Yes. 56 Southern-certified options inside OKNA Windows & Doors Mfg 400 Double Hung satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.22 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many OKNA Windows & Doors Mfg 400 Double Hung variants earn ENERGY STAR Most Efficient?
No. Exactly 25 of 56 configurations (44.6%) earn ENERGY STAR Most Efficient status in 400 Double Hung; the remaining standard v7.0 options pass base zone limits only.
Can homeowners claim Form 5695 credits on OKNA Windows & Doors Mfg 400 Double Hung in 2026?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 400 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
Where are NFRC and IGCC identification marks located on 400 Double Hung?
Inspectors match the temporary NFRC sticker (U 0.17-0.30, SHGC 0.14-0.22) against permit drawings for line OKW-K-22. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg 400 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)