Seven D Windows and Door LLC — 7700/7800 Casement · Casement Windows
Seven D Windows and Door LLC engineered the 7700/7800 Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 55 glass-spacer combinations from 0.17 to 0.27 U-Factor and 0.19 to 0.31 SHGC. Relative to other Vinyl models tracked under NFRC SED, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.17
- SHGC Range
- 0.19-0.31
- Certified Options
- 55
- Category Standing
- #362 of 1,352
How does Seven D Windows and Door LLC 7700/7800 Casement compare thermally against Window peers?
Seven D Windows and Door LLC 7700/7800 Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 7700/7800 Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.27.
Climate coverage for Seven D Windows and Door LLC 7700/7800 Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 11 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-07-02 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 55 certified glazing combinations for 7700/7800 Casement (NFRC SED) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 14 packages (3 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 44 packages (5 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 40 packages (5 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 40 packages (11 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| OKNA Windows & Doors Mfg — 400 Double Hung | Vinyl | 0.17 | 0.14 | 56 |
| OKNA Windows & Doors Mfg — SL620-SL6620 | Vinyl | 0.17 | 0.17 | 56 |
| National Vinyl, LLC — TG/NW3/Destiny/Duratrust/Clarion/Northwind BR Horizontal Slider | Vinyl | 0.17 | 0.22 | 51 |
| Energex Window Alliance — Energex Picture Window | Vinyl | 0.17 | 0.14 | 66 |
| Vector Windows — Envision Glider | Vinyl | 0.17 | 0.17 | 67 |
What other certified series does Seven D Windows and Door LLC produce?
Compare other active Seven D Windows and Door LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
7700/7800 Casement Picture Window
U-Factor 0.14–0.25 · 60 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seven D Windows and Door LLC 7700/7800 Casement appear below.
What thermal performance numbers separate Seven D Windows and Door LLC 7700/7800 Casement from peers?
Seven D Windows and Door LLC 7700/7800 Casement spans 55 certified configurations with U-Factors between 0.17 and 0.27 and SHGC values from 0.19 to 0.31. Ranked #362 of 1,352 Window families, it carries 11 Most Efficient options.
Which glazing options in Seven D Windows and Door LLC 7700/7800 Casement meet Northern climate limits?
Yes. 14 packages in Seven D Windows and Door LLC 7700/7800 Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.27.
What BTU/hr heat transfer results from 7700/7800 Casement's 0.17 minimum U-Factor?
Using NFRC SED U-Factor 0.17, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).
Who should NOT choose Seven D Windows and Door LLC 7700/7800 Casement for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 7700/7800 Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Seven D Windows and Door LLC 7700/7800 Casement in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 40 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Seven D Windows and Door LLC 7700/7800 Casement, while total line SHGC reaches 0.31 in colder packages.
Are all 55 7700/7800 Casement configurations ENERGY STAR Most Efficient?
Within 7700/7800 Casement, 20.0% (11 of 55) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
Do 2026 7700/7800 Casement installations qualify for IRS Section 25C tax credits?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 7700/7800 Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How can homeowners confirm delivered Seven D Windows and Door LLC 7700/7800 Casement units match permits?
Match the NFRC thermal sticker for code SED and line SED-A-44 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Seven D Windows and Door LLC 7700/7800 Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)