Skip to main content
Window · Vinyl Frame NFRC SED · Product Line SED-A-44 ENERGY STAR Most Efficient Eligible

Seven D Windows and Door LLC — 7700/7800 Casement · Casement Windows

Seven D Windows and Door LLC engineered the 7700/7800 Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 55 glass-spacer combinations from 0.17 to 0.27 U-Factor and 0.19 to 0.31 SHGC. Relative to other Vinyl models tracked under NFRC SED, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.19-0.31
Certified Options
55
Category Standing
#362 of 1,352

How does Seven D Windows and Door LLC 7700/7800 Casement compare thermally against Window peers?

Seven D Windows and Door LLC 7700/7800 Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 7700/7800 CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 7700/7800 Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

7700/7800 Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 7700/7800 Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.27.

Climate coverage for Seven D Windows and Door LLC 7700/7800 Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 11 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-07-02 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 55 certified glazing combinations for 7700/7800 Casement (NFRC SED) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 14 packages (3 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 44 packages (5 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 40 packages (5 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 40 packages (11 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Seven D Windows and Door LLC produce?

Compare other active Seven D Windows and Door LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Seven D Windows and Door LLC 7700/7800 Casement appear below.

What thermal performance numbers separate Seven D Windows and Door LLC 7700/7800 Casement from peers?

Seven D Windows and Door LLC 7700/7800 Casement spans 55 certified configurations with U-Factors between 0.17 and 0.27 and SHGC values from 0.19 to 0.31. Ranked #362 of 1,352 Window families, it carries 11 Most Efficient options.

Which glazing options in Seven D Windows and Door LLC 7700/7800 Casement meet Northern climate limits?

Yes. 14 packages in Seven D Windows and Door LLC 7700/7800 Casement clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.27.

What BTU/hr heat transfer results from 7700/7800 Casement's 0.17 minimum U-Factor?

Using NFRC SED U-Factor 0.17, a 15 sq ft Casement Single-Vent (CSSV) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

Who should NOT choose Seven D Windows and Door LLC 7700/7800 Casement for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 7700/7800 Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Can you install Seven D Windows and Door LLC 7700/7800 Casement in Southern or South-Central zones?

Across Northern, North-Central, South-Central, Southern, 40 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Seven D Windows and Door LLC 7700/7800 Casement, while total line SHGC reaches 0.31 in colder packages.

Are all 55 7700/7800 Casement configurations ENERGY STAR Most Efficient?

Within 7700/7800 Casement, 20.0% (11 of 55) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

Do 2026 7700/7800 Casement installations qualify for IRS Section 25C tax credits?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 7700/7800 Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Seven D Windows and Door LLC 7700/7800 Casement units match permits?

Match the NFRC thermal sticker for code SED and line SED-A-44 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Seven D Windows and Door LLC 7700/7800 Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros