Skip to main content
Window · Vinyl Frame NFRC OKW · Product Line OKW-K-39 ENERGY STAR Most Efficient Eligible

OKNA Windows & Doors Mfg — SL620-SL6620 · Double Slider

Positioning #362/1,352 in certified Window, OKNA Windows & Doors Mfg SL620-SL6620 pairs Vinyl frame construction with 56 glazing options rated between 0.17 and 0.23 SHGC across Northern, North-Central, South-Central, Southern. Across 21 certified OKNA Windows & Doors Mfg product families, its thermal resistance spans 0.17 to 0.30 U-Factor and the line includes 14 ENERGY STAR Most Efficient packages (25.0% of line).

Min U-Factor
0.17
SHGC Range
0.17-0.23
Certified Options
56
Category Standing
#362 of 1,352

How does OKNA Windows & Doors Mfg SL620-SL6620 compare thermally against Window peers?

OKNA Windows & Doors Mfg SL620-SL6620 achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. SL620-SL6620Histogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing SL620-SL6620 (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

SL620-SL6620 Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), SL620-SL6620 reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID OKW across multi-pane fills shifts U-Factor from 0.30 down toward 0.17.

Regional qualification covers Northern, North-Central, South-Central, Southern. 14 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-05 licensing and 2026-07-13 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 56 certified glazing combinations for SL620-SL6620 (NFRC OKW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 14 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 14 packages (14 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 52 packages (14 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 56 packages (14 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does OKNA Windows & Doors Mfg produce?

Compare other active OKNA Windows & Doors Mfg certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to OKNA Windows & Doors Mfg SL620-SL6620 appear below.

What thermal performance numbers separate OKNA Windows & Doors Mfg SL620-SL6620 from peers?

EPA ENERGY STAR v7.0 records 56 configurations for OKNA Windows & Doors Mfg SL620-SL6620 covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 14 options earn Most Efficient status.

Is SL620-SL6620 approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 14 SL620-SL6620 packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.30, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from SL620-SL6620's 0.17 minimum U-Factor?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make SL620-SL6620 the wrong window or door choice?

Skip SL620-SL6620 if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on SL620-SL6620 options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in SL620-SL6620?

Warm-climate homeowners have 56 Southern-approved options within SL620-SL6620 spanning SHGC down to 0.17. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Are all 56 SL620-SL6620 configurations ENERGY STAR Most Efficient?

No. Exactly 14 of 56 configurations (25.0%) earn ENERGY STAR Most Efficient status in SL620-SL6620; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect SL620-SL6620?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

Where are NFRC and IGCC identification marks located on SL620-SL6620?

Match the NFRC thermal sticker for code OKW and line OKW-K-39 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for OKNA Windows & Doors Mfg SL620-SL6620 come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)