Skip to main content
Window · Vinyl Frame NFRC EWA · Product Line EWA-K-3 ENERGY STAR Most Efficient Eligible

Energex Window Alliance — Energex Picture Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 66 variants inside Energex Window Alliance Energex Picture Window, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.27 and SHGC 0.14 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.17
SHGC Range
0.14-0.52
Certified Options
66
Category Standing
#362 of 1,352

How does Energex Window Alliance Energex Picture Window compare thermally against Window peers?

Energex Window Alliance Energex Picture Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Energex Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Energex Picture Window (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Energex Picture Window Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Energex Picture Window spans 66 NFRC test records (EWA), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.02 against the Vinyl median (0.19).

Climate coverage for Energex Window Alliance Energex Picture Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 10 configurations meet ENERGY STAR Most Efficient criteria while 18 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-03-28 and cert timestamp 2025-07-31.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 66 certified glazing combinations for Energex Picture Window (NFRC EWA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 18 packages (9 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 51 packages (5 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 34 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 34 packages (5 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vector Windows — Envision Glider Vinyl 0.17 0.17 67
Vector Windows — Envision Single Hung Vinyl 0.17 0.17 68
OKNA Windows & Doors Mfg — SL420 Horizontal Slider Vinyl 0.17 0.14 72
Walsh Building Products — 6300 Picture Window Vinyl 0.17 0.20 74
OKNA Windows & Doors Mfg — 400 Double Hung Vinyl 0.17 0.14 56

What other certified series does Energex Window Alliance produce?

Compare other active Energex Window Alliance certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Energex Window Alliance Energex Picture Window appear below.

What thermal performance numbers separate Energex Window Alliance Energex Picture Window from peers?

Across 66 tested NFRC glazing configurations, Energex Window Alliance Energex Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.17 minimum U-Factor and 0.14-0.52 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

Does Energex Window Alliance Energex Picture Window qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 18 compliant Northern packages inside Energex Picture Window, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.27 options.

What BTU/hr heat transfer results from Energex Picture Window's 0.17 minimum U-Factor?

At U 0.17, a standard 3x5 ft (15 sq ft) Energex Picture Window opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

Who should NOT choose Energex Window Alliance Energex Picture Window for a residential project?

Skip Energex Picture Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Energex Picture Window options exceeding U 0.22.

Is Energex Picture Window suitable for sunbelt cooling-dominated homes?

Yes, Energex Picture Window holds 34 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.

How many Energex Window Alliance Energex Picture Window variants earn ENERGY STAR Most Efficient?

EPA lists 10 Most Efficient options (15.2% share) inside Energex Window Alliance Energex Picture Window, out of 66 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Energex Window Alliance Energex Picture Window in 2026?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 Energex Picture Window installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

How can homeowners confirm delivered Energex Window Alliance Energex Picture Window units match permits?

Verify NFRC ID EWA and series EWA-K-3 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Energex Window Alliance Energex Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros