Skip to main content
Window · Vinyl Frame NFRC EWA · Product Line EWA-K-1 ENERGY STAR Most Efficient Eligible

Energex Window Alliance — Energex Slider · Double Slider

Positioning #564/1,352 in certified Window, Energex Window Alliance Energex Slider pairs Vinyl frame construction with 91 glazing options rated between 0.13 and 0.46 SHGC across Northern, North-Central, South-Central, Southern. Across 6 certified Energex Window Alliance product families, its thermal resistance spans 0.19 to 0.29 U-Factor and the line includes 17 ENERGY STAR Most Efficient packages (18.7% of line).

Min U-Factor
0.19
SHGC Range
0.13-0.46
Certified Options
91
Category Standing
#564 of 1,352

How does Energex Window Alliance Energex Slider compare thermally against Window peers?

Energex Window Alliance Energex Slider achieves a 0.19 thermal floor across Window lines, placing #564 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Energex SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing Energex Slider (U 0.19).249<=0.153140.16-0.182670.19-0.21This model: U 0.193430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Energex Slider Cohort StandingMin U-Factor 0.19 stands at rank #564 of 1,352, outperforming 50.4% of peers.Min U-Factor 0.19Rank #564 of 1,352 (50.4% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified Energex Window Alliance series, this Double Slider offers a 0.10 U-Factor adjustment span between 0.29 entry options and 0.19 top-performing glazing. Category standing is #564/1,352 (tied with 106 others at 0.19, more insulating than 50.4% of Window lines, top 49.6%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 17 configurations meet ENERGY STAR Most Efficient criteria while 29 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.19 U-Factor yields 114.0 BTU/hr transfer (-18.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-03-28 licensing and 2025-07-24 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 91 certified glazing combinations for Energex Slider (NFRC EWA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 29 packages (5 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 74 packages (5 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 64 packages (4 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 65 packages (14 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.19 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Northeast Building Products Corporation — Elite NC PW Vinyl 0.19 0.16 77
Northeast Building Products Corporation — Elite DH PW Vinyl 0.19 0.17 76
Soft-Lite, LLC — Elements DH20 Double Hung Vinyl 0.19 0.16 68
Soft-Lite, LLC — Imperial Elite DH12E Vinyl 0.19 0.16 68
Vinyl Kraft, Inc. — 2000/2500 Single Hung Vinyl 0.19 0.17 68

What other certified series does Energex Window Alliance produce?

Compare other active Energex Window Alliance certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Energex Window Alliance Energex Slider appear below.

What U-Factor and SHGC range does Energex Window Alliance Energex Slider achieve?

Testing puts Energex Window Alliance Energex Slider at rank #564 of 1,352 Window entries with U 0.19 to 0.29 across 91 configurations. Solar heat gain ranges between 0.13 and 0.46 across Northern, North-Central, South-Central, Southern.

How does Energex Window Alliance Energex Slider satisfy Version 7.0 Northern criteria?

Yes, 29 packages satisfy Northern ENERGY STAR Version 7.0 rules in Energex Slider. Pairing multi-pane insulation down to 0.19 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates Energex Slider from the 0.22 Northern rule?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.19 U-Factor yields 114.0 BTU/hr conductive transfer (-13.6% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make Energex Slider the wrong window or door choice?

Skip Energex Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Energex Slider options exceeding U 0.22.

What Southern ENERGY STAR v7.0 options exist in Energex Slider?

Yes. 65 Southern-certified options inside Energex Window Alliance Energex Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.46 SHGC on west-facing glass to avoid excess afternoon solar gain.

What glazing share inside Energex Slider qualifies as Most Efficient?

Within Energex Slider, 18.7% (17 of 91) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What 2026 federal tax credit and Lead RRP rules apply to Energex Slider?

Any Energex Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Energex Slider?

Inspectors match the temporary NFRC sticker (U 0.19-0.29, SHGC 0.13-0.46) against permit drawings for line EWA-K-1. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Energex Window Alliance Energex Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros