Skip to main content
Window · Vinyl Frame NFRC EWA · Product Line EWA-K-2 ENERGY STAR Most Efficient Eligible

Energex Window Alliance — Energex Double Hung · Double Hung

Energex Window Alliance Energex Double Hung is a Double Hung assembly with a Vinyl frame that reaches a minimum U-Factor of 0.17 across 107 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #362 of 1,352 in Window, its thermal floor is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.13 to 0.48.

Min U-Factor
0.17
SHGC Range
0.13-0.48
Certified Options
107
Category Standing
#362 of 1,352

How does Energex Window Alliance Energex Double Hung compare thermally against Window peers?

Energex Window Alliance Energex Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Energex Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Energex Double Hung (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Energex Double Hung Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified Energex Window Alliance series, this Double Hung offers a 0.12 U-Factor adjustment span between 0.29 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 22 configurations meet ENERGY STAR Most Efficient criteria while 38 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-03-28 and v7.0 data certification on 2025-07-24. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 107 certified glazing combinations for Energex Double Hung (NFRC EWA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 38 packages (9 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 90 packages (9 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 61 packages (6 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 62 packages (17 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Energex Window Alliance produce?

Compare other active Energex Window Alliance certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Energex Window Alliance Energex Double Hung appear below.

Where does Energex Window Alliance Energex Double Hung stand thermally among ENERGY STAR Window lines?

Testing puts Energex Window Alliance Energex Double Hung at rank #362 of 1,352 Window entries with U 0.17 to 0.29 across 107 configurations. Solar heat gain ranges between 0.13 and 0.48 across Northern, North-Central, South-Central, Southern.

Which glazing options in Energex Window Alliance Energex Double Hung meet Northern climate limits?

Prescriptive Northern compliance covers 38 Energex Double Hung packages (U floor 0.17, SHGC >= 0.17). Because the complete series stretches up to U 0.29, specify the cold-climate glass code explicitly.

How do you calculate winter heat conduction for Energex Window Alliance Energex Double Hung?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

What homeowner profiles are a poor match for Energex Window Alliance Energex Double Hung?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Energex Double Hung options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

What Southern ENERGY STAR v7.0 options exist in Energex Double Hung?

Across Northern, North-Central, South-Central, Southern, 62 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Energex Window Alliance Energex Double Hung, while total line SHGC reaches 0.48 in colder packages.

What glazing share inside Energex Double Hung qualifies as Most Efficient?

EPA lists 22 Most Efficient options (20.6% share) inside Energex Window Alliance Energex Double Hung, out of 107 total Version 7.0 entries.

Can homeowners claim Form 5695 credits on Energex Window Alliance Energex Double Hung in 2026?

No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.

How can homeowners confirm delivered Energex Window Alliance Energex Double Hung units match permits?

Verify NFRC ID EWA and series EWA-K-2 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Energex Window Alliance Energex Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros