Skip to main content
Window · Vinyl Frame NFRC EWA · Product Line EWA-K-4 ENERGY STAR Most Efficient Eligible

Energex Window Alliance — Energex Casement · Casement Windows

Across 6 Energex Window Alliance certified families, Energex Casement supplies 186 Casement Windows configurations starting at 0.17 U-Factor and 0.13 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.27 U-Factor and 0.29 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.13-0.29
Certified Options
186
Category Standing
#362 of 1,352

How does Energex Window Alliance Energex Casement compare thermally against Window peers?

Energex Window Alliance Energex Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Energex CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Energex Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Energex Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), Energex Casement reaches 0.17 on its lowest-conductivity package — #271 of 1,009 in Vinyl, tied with 82 others at 0.17, more insulating than 65.0% of Vinyl lines, top 35.0% (-0.02 vs Vinyl peers). Pairing NFRC ID EWA across multi-pane fills shifts U-Factor from 0.27 down toward 0.17.

Climate coverage for Energex Window Alliance Energex Casement spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 63 configurations meet ENERGY STAR Most Efficient criteria while 71 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-03-28 licensing and 2024-02-13 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 186 certified glazing combinations for Energex Casement (NFRC EWA) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 71 packages (28 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 166 packages (43 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 113 packages (31 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 113 packages (51 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Energex Window Alliance produce?

Compare other active Energex Window Alliance certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Energex Window Alliance Energex Casement appear below.

What thermal performance numbers separate Energex Window Alliance Energex Casement from peers?

Energex Window Alliance Energex Casement spans 186 certified configurations with U-Factors between 0.17 and 0.27 and SHGC values from 0.13 to 0.29. Ranked #362 of 1,352 Window families, it carries 63 Most Efficient options.

How does Energex Window Alliance Energex Casement satisfy Version 7.0 Northern criteria?

Energex Window Alliance Energex Casement supplies 71 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.27, so inspect the NFRC order sheet before purchase.

How do you calculate winter heat conduction for Energex Window Alliance Energex Casement?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.17 U-Factor yields 102.0 BTU/hr conductive transfer (-22.7% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

When should a buyer skip Energex Window Alliance Energex Casement and compare alternatives?

Skip Energex Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on Energex Casement options exceeding U 0.22.

Does Energex Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Exactly 113 Energex Casement options qualify for the Southern Zone (SHGC <= 0.23, U <= 0.32, air <= 0.3 cfm/ft2). Confirm the low-SHGC Low-E coating near 0.13 rather than higher 0.29 glass.

Which package tier in Energex Casement holds Most Efficient recognition?

Only 63 options out of 186 (33.9%) meet tighter Most Efficient U-Factor and SHGC thresholds in Energex Window Alliance Energex Casement, usually requiring triple-pane or upgraded Low-E coatings.

How do the 25C sunset and pre-1978 Lead RRP rules affect Energex Casement?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current Energex Casement retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered Energex Window Alliance Energex Casement units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code EWA and product line EWA-K-4, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Energex Window Alliance Energex Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros