Skip to main content
Window · Vinyl Frame NFRC GAM · Product Line GAM-M-19 ENERGY STAR Most Efficient Eligible

Comfort Window Manufacturing, Inc. — TrustSeries Casement Picture Window · Picture Window

Across 6 Comfort Window Manufacturing, Inc. certified families, TrustSeries Casement Picture Window supplies 180 Picture Window configurations starting at 0.17 U-Factor and 0.19 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.27 U-Factor and 0.52 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.19-0.52
Certified Options
180
Category Standing
#362 of 1,352

How does Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window compare thermally against Window peers?

Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. TrustSeries Casement Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing TrustSeries Casement Picture Window (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

TrustSeries Casement Picture Window Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 6 certified Comfort Window Manufacturing, Inc. series, this Picture Window offers a 0.10 U-Factor adjustment span between 0.27 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 39 configurations meet ENERGY STAR Most Efficient criteria while 123 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-02-21 and cert timestamp 2024-12-04.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 180 certified glazing combinations for TrustSeries Casement Picture Window (NFRC GAM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 123 packages (26 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 108 packages (16 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 37 packages (10 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 37 packages (23 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Comfort Window Manufacturing, Inc. produce?

Compare other active Comfort Window Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window appear below.

What U-Factor and SHGC range does Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window achieve?

Built with Vinyl framing in Fixed Window (FIXD) style, Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window offers 180 Version 7.0 configurations from U 0.17 up to 0.27, posting -0.03 against the Window median of 0.20 with 39 Most Efficient picks.

How does Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 123 compliant Northern packages inside TrustSeries Casement Picture Window, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.27 options.

What conductive BTU/hr difference separates TrustSeries Casement Picture Window from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), TrustSeries Casement Picture Window at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

What homeowner profiles are a poor match for Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on TrustSeries Casement Picture Window options exceeding U 0.22. Additionally, do not order Fixed Window (FIXD) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is TrustSeries Casement Picture Window suitable for sunbelt cooling-dominated homes?

Yes. 37 Southern-certified options inside Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.52 SHGC on west-facing glass to avoid excess afternoon solar gain.

Are all 180 TrustSeries Casement Picture Window configurations ENERGY STAR Most Efficient?

Not every package qualifies: 39 of 180 TrustSeries Casement Picture Window glazing builds earn Most Efficient recognition (21.7%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect TrustSeries Casement Picture Window?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Comfort Window Manufacturing, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window units match permits?

Inspectors match the temporary NFRC sticker (U 0.17-0.27, SHGC 0.19-0.52) against permit drawings for line GAM-M-19. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Comfort Window Manufacturing, Inc. TrustSeries Casement Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)