Skip to main content
Window · Vinyl Frame NFRC GAM · Product Line GAM-M-13 ENERGY STAR Most Efficient Eligible

Comfort Window Manufacturing, Inc. — Duraguard Picture Window · Picture Window

Across 6 Comfort Window Manufacturing, Inc. certified families, Duraguard Picture Window supplies 160 Picture Window configurations starting at 0.16 U-Factor and 0.20 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.26 U-Factor and 0.54 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.20-0.54
Certified Options
160
Category Standing
#250 of 1,352

How does Comfort Window Manufacturing, Inc. Duraguard Picture Window compare thermally against Window peers?

Comfort Window Manufacturing, Inc. Duraguard Picture Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Duraguard Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Duraguard Picture Window (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Duraguard Picture Window Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across Duraguard Picture Window spans 160 NFRC test records (GAM), ranking #250 of 1,352 Window families (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Mapping NFRC SHGC values (0.20 to 0.54) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 32 configurations meet ENERGY STAR Most Efficient criteria while 112 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-02-21 and v7.0 data certification on 2024-12-04. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 160 certified glazing combinations for Duraguard Picture Window (NFRC GAM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 112 packages (26 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 104 packages (16 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 26 packages (8 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 26 packages (14 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Comfort Window Manufacturing, Inc. produce?

Compare other active Comfort Window Manufacturing, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Comfort Window Manufacturing, Inc. Duraguard Picture Window appear below.

How efficient is Comfort Window Manufacturing, Inc. Duraguard Picture Window compared with peer Window models?

Across 160 tested NFRC glazing configurations, Comfort Window Manufacturing, Inc. Duraguard Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.16 minimum U-Factor and 0.20-0.54 SHGC band. It places #250 among 1,352 Window series—top 26.7%.

How does Comfort Window Manufacturing, Inc. Duraguard Picture Window satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 112 compliant Northern packages inside Duraguard Picture Window, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.26 options.

How does a 3x5 ft Duraguard Picture Window window perform under a 40 deg F temperature drop?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on Duraguard Picture Window's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.26 transfer proportionally more energy.

When should a buyer skip Comfort Window Manufacturing, Inc. Duraguard Picture Window and compare alternatives?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on Duraguard Picture Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

Is Duraguard Picture Window suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 26 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Comfort Window Manufacturing, Inc. Duraguard Picture Window, while total line SHGC reaches 0.54 in colder packages.

What glazing share inside Duraguard Picture Window qualifies as Most Efficient?

Within Duraguard Picture Window, 20.0% (32 of 160) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 Duraguard Picture Window window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Comfort Window Manufacturing, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Comfort Window Manufacturing, Inc. Duraguard Picture Window units match permits?

Match the NFRC thermal sticker for code GAM and line GAM-M-13 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Comfort Window Manufacturing, Inc. Duraguard Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros