Skip to main content
Window · Vinyl Frame NFRC LWW · Product Line LWW-K-22 ENERGY STAR Most Efficient Eligible

Lindsay Windows — ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement · Picture Window

EPA ENERGY STAR Version 7.0 certifies 156 variants inside Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.28 and SHGC 0.18 to 0.52. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.17
SHGC Range
0.18-0.52
Certified Options
156
Category Standing
#362 of 1,352

How does Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement compare thermally against Window peers?

Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement is 0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.17-0.28.

Regional qualification covers Northern, North-Central, South-Central, Southern. 48 configurations meet ENERGY STAR Most Efficient criteria while 104 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2022-10-20 and v7.0 data certification on 2024-02-22. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.17 conducts 102.0 BTU/hr (-30.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 156 certified glazing combinations for ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement (NFRC LWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 104 packages (16 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 118 packages (12 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 65 packages (7 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 65 packages (36 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
NT Window, Inc. — C100/G100-Casement Vinyl 0.17 0.11 156
Mercury Excelum, Inc. — EOS\EOS+\ICON Double Hung Vinyl 0.17 0.16 148
NT Window, Inc. — A100-Awning Vinyl 0.17 0.11 148
Comfort Window Manufacturing, Inc. — TrustSeries Awning Vinyl 0.17 0.16 171
Comfort Window Manufacturing, Inc. — TrustSeries Casement Vinyl 0.17 0.16 175

What other certified series does Lindsay Windows produce?

Compare other active Lindsay Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement appear below.

Where does Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement stand thermally among ENERGY STAR Window lines?

Across 156 tested NFRC glazing configurations, Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement with Vinyl framing and Fixed Window (FIXD) style reaches a 0.17 minimum U-Factor and 0.18-0.52 SHGC band. It places #362 among 1,352 Window series—top 35.2%.

Does Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement qualify for the ENERGY STAR Northern Zone?

Cold-climate buyers get 104 compliant Northern packages inside ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.28 options.

What BTU/hr heat transfer results from ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement's 0.17 minimum U-Factor?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.28 transfer proportionally more energy.

What homeowner profiles are a poor match for Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement?

Do not specify ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Does ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Across Northern, North-Central, South-Central, Southern, 65 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement, while total line SHGC reaches 0.52 in colder packages.

What glazing share inside ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement qualifies as Most Efficient?

Only 48 options out of 156 (30.8%) meet tighter Most Efficient U-Factor and SHGC thresholds in Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement, usually requiring triple-pane or upgraded Low-E coatings.

What 2026 federal tax credit and Lead RRP rules apply to ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Lindsay Windows upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement glass specs on job sites?

Match the NFRC thermal sticker for code LWW and line LWW-K-22 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lindsay Windows ClimateSmart / SunView / CrownView / Pinnacle / Healthy Fixed Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros