Skip to main content
Window · Vinyl Frame NFRC NTW · Product Line NTW-A-30 ENERGY STAR Most Efficient Eligible

NT Window, Inc. — A100-Awning · Awning (Projected)

Positioning #362/1,352 in certified Window, NT Window, Inc. A100-Awning pairs Vinyl frame construction with 148 glazing options rated between 0.11 and 0.21 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified NT Window, Inc. product families, its thermal resistance spans 0.17 to 0.28 U-Factor and the line includes 55 ENERGY STAR Most Efficient packages (37.2% of line).

Min U-Factor
0.17
SHGC Range
0.11-0.21
Certified Options
148
Category Standing
#362 of 1,352

How does NT Window, Inc. A100-Awning compare thermally against Window peers?

NT Window, Inc. A100-Awning achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. A100-AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing A100-Awning (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

A100-Awning Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 13 certified NT Window, Inc. series, this Awning, Projected offers a 0.11 U-Factor adjustment span between 0.28 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Regional qualification covers Northern, North-Central, South-Central, Southern. 55 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.17 U-Factor yields 102.0 BTU/hr transfer (-30.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-04-26 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 148 certified glazing combinations for A100-Awning (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 12 packages (4 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 95 packages (39 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 148 packages (39 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 148 packages (55 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. A100-Awning appear below.

What thermal performance numbers separate NT Window, Inc. A100-Awning from peers?

EPA ENERGY STAR v7.0 records 148 configurations for NT Window, Inc. A100-Awning covering Northern, North-Central, South-Central, Southern, dropping down to U 0.17 versus a 0.20 Window median. Only 55 options earn Most Efficient status.

How does NT Window, Inc. A100-Awning satisfy Version 7.0 Northern criteria?

Yes, 12 packages satisfy Northern ENERGY STAR Version 7.0 rules in A100-Awning. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates A100-Awning from the 0.22 Northern rule?

At U 0.17, a standard 3x5 ft (15 sq ft) A100-Awning opening transfers 102.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -30.0 BTU/hr difference.

What homeowner profiles are a poor match for NT Window, Inc. A100-Awning?

Skip A100-Awning if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on A100-Awning options exceeding U 0.22.

Does A100-Awning meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 148 Southern-certified options inside NT Window, Inc. A100-Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.21 SHGC on west-facing glass to avoid excess afternoon solar gain.

Does A100-Awning carry EPA Most Efficient certification across its lineup?

No. Exactly 55 of 148 configurations (37.2%) earn ENERGY STAR Most Efficient status in A100-Awning; the remaining standard v7.0 options pass base zone limits only.

How do the 25C sunset and pre-1978 Lead RRP rules affect A100-Awning?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current A100-Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

What permanent glass etch marks verify A100-Awning after sticker removal?

Match the NFRC thermal sticker for code NTW and line NTW-A-30 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. A100-Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)