Skip to main content
Window · Vinyl Frame NFRC NTW · Product Line NTW-A-28 ENERGY STAR Most Efficient Eligible

NT Window, Inc. — C150 - Casement Picture Window · Picture Window

Positioning #250/1,352 in certified Window, NT Window, Inc. C150 - Casement Picture Window pairs Vinyl frame construction with 140 glazing options rated between 0.13 and 0.21 SHGC across Northern, North-Central, South-Central, Southern. Across 13 certified NT Window, Inc. product families, its thermal resistance spans 0.16 to 0.28 U-Factor and the line includes 61 ENERGY STAR Most Efficient packages (43.6% of line).

Min U-Factor
0.16
SHGC Range
0.13-0.21
Certified Options
140
Category Standing
#250 of 1,352

How does NT Window, Inc. C150 - Casement Picture Window compare thermally against Window peers?

NT Window, Inc. C150 - Casement Picture Window achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. C150 - Casement Picture WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing C150 - Casement Picture Window (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

C150 - Casement Picture Window Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), C150 - Casement Picture Window is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.28.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 61 configurations meet ENERGY STAR Most Efficient criteria while 31 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-05-10 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 140 certified glazing combinations for C150 - Casement Picture Window (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 31 packages (1 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 97 packages (36 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 140 packages (36 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 140 packages (61 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. C150 - Casement Picture Window appear below.

What thermal performance numbers separate NT Window, Inc. C150 - Casement Picture Window from peers?

Across 140 tested NFRC glazing configurations, NT Window, Inc. C150 - Casement Picture Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.16 minimum U-Factor and 0.13-0.21 SHGC band. It places #250 among 1,352 Window series—top 26.7%.

Is C150 - Casement Picture Window approved for Northern Zone heating climates?

Prescriptive Northern compliance covers 31 C150 - Casement Picture Window packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from C150 - Casement Picture Window's 0.16 minimum U-Factor?

At U 0.16, a standard 3x5 ft (15 sq ft) C150 - Casement Picture Window opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

What homeowner profiles are a poor match for NT Window, Inc. C150 - Casement Picture Window?

Cold-climate owners needing prescriptive U <= 0.22 should pass on C150 - Casement Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in C150 - Casement Picture Window?

Yes, C150 - Casement Picture Window holds 140 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

Are all 140 C150 - Casement Picture Window configurations ENERGY STAR Most Efficient?

Not every package qualifies: 61 of 140 C150 - Casement Picture Window glazing builds earn Most Efficient recognition (43.6%), while other variants sit on the standard Version 7.0 tier.

What federal compliance checks govern 2026 C150 - Casement Picture Window window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 NT Window, Inc. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

What permanent glass etch marks verify C150 - Casement Picture Window after sticker removal?

Confirm both the paper NFRC label and permanent corner glass etch match line NTW-A-28 and NFRC ID NTW before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. C150 - Casement Picture Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros