Window · Vinyl Frame NFRC NTW · Product Line NTW-A-33 ENERGY STAR Most Efficient Eligible

NT Window, Inc. — F110/G110 RR/NC Single Hung · Single Hung

EPA ENERGY STAR Version 7.0 certifies 96 variants inside NT Window, Inc. F110/G110 RR/NC Single Hung, combining Vinyl frame construction with U-Factors spanning 0.17 to 0.29 and SHGC 0.13 to 0.22. Qualifying for Northern, North-Central, South-Central, Southern, this Single Hung family places #362 of 1,352 among 1,352 Window families and posts 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.17
SHGC Range
0.13-0.22
Certified Options
96
Category Standing
#362 of 1,352

How does NT Window, Inc. F110/G110 RR/NC Single Hung compare thermally against Window peers?

NT Window, Inc. F110/G110 RR/NC Single Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. F110/G110 RR/NC Single HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing F110/G110 RR/NC Single Hung (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

F110/G110 RR/NC Single Hung Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows NT Window, Inc. F110/G110 RR/NC Single Hung standing at #362 of 1,352 certified Window product series, tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%. Comparing Vinyl profiles alone (median 0.19) shows -0.02 before selecting Low-E tiers.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 24 configurations meet ENERGY STAR Most Efficient criteria while 12 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Lifecycle documentation anchors NTW to 2026-08-06 certification (FENSTAR issued 2018-01-10). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 96 certified glazing combinations for F110/G110 RR/NC Single Hung (NFRC NTW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 12 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 48 packages (16 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 94 packages (16 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 96 packages (24 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does NT Window, Inc. produce?

Compare other active NT Window, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to NT Window, Inc. F110/G110 RR/NC Single Hung appear below.

How efficient is NT Window, Inc. F110/G110 RR/NC Single Hung compared with peer Window models?

Built with Vinyl framing in Single-Hung (VSSH) style, NT Window, Inc. F110/G110 RR/NC Single Hung offers 96 Version 7.0 configurations from U 0.17 up to 0.29, posting -0.03 against the Window median of 0.20 with 24 Most Efficient picks.

Is F110/G110 RR/NC Single Hung approved for Northern Zone heating climates?

Yes. 12 packages in NT Window, Inc. F110/G110 RR/NC Single Hung clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.29.

What BTU/hr heat transfer results from F110/G110 RR/NC Single Hung's 0.17 minimum U-Factor?

Using NFRC NTW U-Factor 0.17, a 15 sq ft Single-Hung (VSSH) assembly conducts 102.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-30.0 BTU/hr margin).

Who should NOT choose NT Window, Inc. F110/G110 RR/NC Single Hung for a residential project?

Do not specify F110/G110 RR/NC Single Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on F110/G110 RR/NC Single Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

Is F110/G110 RR/NC Single Hung suitable for sunbelt cooling-dominated homes?

Across Northern, North-Central, South-Central, Southern, 96 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside NT Window, Inc. F110/G110 RR/NC Single Hung, while total line SHGC reaches 0.22 in colder packages.

Does F110/G110 RR/NC Single Hung carry EPA Most Efficient certification across its lineup?

Only 24 options out of 96 (25.0%) meet tighter Most Efficient U-Factor and SHGC thresholds in NT Window, Inc. F110/G110 RR/NC Single Hung, usually requiring triple-pane or upgraded Low-E coatings.

Can homeowners claim Form 5695 credits on NT Window, Inc. F110/G110 RR/NC Single Hung in 2026?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current F110/G110 RR/NC Single Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How can homeowners confirm delivered NT Window, Inc. F110/G110 RR/NC Single Hung units match permits?

Match the NFRC thermal sticker for code NTW and line NTW-A-33 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for NT Window, Inc. F110/G110 RR/NC Single Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros