Skip to main content
Window · Vinyl Frame NFRC LWW · Product Line LWW-K-11 ENERGY STAR Most Efficient Eligible

Lindsay Windows — Pinnacle / Healthy Double Hung · Double Hung

Lindsay Windows engineered the Pinnacle / Healthy Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 1,344 glass-spacer combinations from 0.17 to 0.29 U-Factor and 0.16 to 0.47 SHGC. Relative to other Vinyl models tracked under NFRC LWW, its minimum U-Factor is 0.02 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.17
SHGC Range
0.16-0.47
Certified Options
1,344
Category Standing
#362 of 1,352

How does Lindsay Windows Pinnacle / Healthy Double Hung compare thermally against Window peers?

Lindsay Windows Pinnacle / Healthy Double Hung achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. Pinnacle / Healthy Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing Pinnacle / Healthy Double Hung (U 0.17).249<=0.153140.16-0.18This model: U 0.172670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

Pinnacle / Healthy Double Hung Cohort StandingMin U-Factor 0.17 stands at rank #362 of 1,352, outperforming 64.8% of peers.Min U-Factor 0.17Rank #362 of 1,352 (64.8% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 16 certified Lindsay Windows series, this Double Hung offers a 0.12 U-Factor adjustment span between 0.29 entry options and 0.17 top-performing glazing. Category standing is #362/1,352 (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%).

Mapping NFRC SHGC values (0.16 to 0.47) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 484 configurations meet ENERGY STAR Most Efficient criteria while 728 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 102.0 BTU/hr (-22.7% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2022-10-20 and cert timestamp 2024-04-29.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,344 certified glazing combinations for Pinnacle / Healthy Double Hung (NFRC LWW) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 728 packages (186 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,016 packages (281 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 726 packages (169 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 736 packages (328 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Vinylmax LLC — CP74 Picture Window Vinyl 0.17 0.14 1,603
Windsor Windows and Doors — Next Dimension Casement Picture Vinyl 0.17 0.12 1,610
DRUTEX S.A. — IGLO 5 Classic Tilt Turn Vinyl 0.17 0.04 1,631
Amsco Windows — VLS STC Serenity Horizontal Slider Vinyl 0.17 0.11 912
Amsco Windows — VLS STC Serenity Single Hung Vinyl 0.17 0.11 912

What other certified series does Lindsay Windows produce?

Compare other active Lindsay Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Lindsay Windows Pinnacle / Healthy Double Hung appear below.

How well does Pinnacle / Healthy Double Hung by Lindsay Windows insulate relative to Window benchmarks?

Built with Vinyl framing in Double-Hung (VSDH) style, Lindsay Windows Pinnacle / Healthy Double Hung offers 1,344 Version 7.0 configurations from U 0.17 up to 0.29, posting -0.03 against the Window median of 0.20 with 484 Most Efficient picks.

Which glazing options in Lindsay Windows Pinnacle / Healthy Double Hung meet Northern climate limits?

Cold-climate buyers get 728 compliant Northern packages inside Pinnacle / Healthy Double Hung, reaching down to U 0.17. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.29 options.

How do you calculate winter heat conduction for Lindsay Windows Pinnacle / Healthy Double Hung?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), Pinnacle / Healthy Double Hung at U 0.17 conducts 102.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

When should a buyer skip Lindsay Windows Pinnacle / Healthy Double Hung and compare alternatives?

Cold-climate owners needing prescriptive U <= 0.22 should pass on Pinnacle / Healthy Double Hung options exceeding U 0.22. Additionally, do not order Double-Hung (VSDH) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

What Southern ENERGY STAR v7.0 options exist in Pinnacle / Healthy Double Hung?

Warm-climate homeowners have 736 Southern-approved options within Pinnacle / Healthy Double Hung spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Which package tier in Pinnacle / Healthy Double Hung holds Most Efficient recognition?

Within Pinnacle / Healthy Double Hung, 36.0% (484 of 1,344) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What 2026 federal tax credit and Lead RRP rules apply to Pinnacle / Healthy Double Hung?

Any Pinnacle / Healthy Double Hung purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

Where are NFRC and IGCC identification marks located on Pinnacle / Healthy Double Hung?

Inspectors match the temporary NFRC sticker (U 0.17-0.29, SHGC 0.16-0.47) against permit drawings for line LWW-K-11. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Lindsay Windows Pinnacle / Healthy Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros