DRUTEX S.A. — IGLO 5 Classic Tilt Turn · Dual Action (Tilt Turn)
Across 40 DRUTEX S.A. certified families, IGLO 5 Classic Tilt Turn supplies 1,631 Dual Action, Tilt Turn configurations starting at 0.17 U-Factor and 0.04 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.32 U-Factor and 0.39 SHGC. Its thermal floor ranks #362 of 1,352 category entries—0.03 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.17
- SHGC Range
- 0.04-0.39
- Certified Options
- 1,631
- Category Standing
- #362 of 1,352
How does DRUTEX S.A. IGLO 5 Classic Tilt Turn compare thermally against Window peers?
DRUTEX S.A. IGLO 5 Classic Tilt Turn achieves a 0.17 thermal floor across Window lines, placing #362 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across IGLO 5 Classic Tilt Turn spans 1,631 NFRC test records (DRU), ranking #362 of 1,352 Window families (tied with 114 others at 0.17, more insulating than 64.8% of Window lines, top 35.2%). Its 0.17 thermal floor compares at -0.02 against the Vinyl median (0.19).
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 498 configurations meet ENERGY STAR Most Efficient criteria while 666 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Lifecycle documentation anchors DRU to 2023-10-19 certification (FENSTAR issued 2023-04-03). Applying Q = U * Area * dT on 15 sq ft at 40°F generates 102.0 BTU/hr conductive loss (-22.7% vs the 132.0 BTU/hr baseline at U=0.22).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,631 certified glazing combinations for IGLO 5 Classic Tilt Turn (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 666 packages (284 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,169 packages (369 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 675 packages (130 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 948 packages (259 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.17 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Windsor Windows and Doors — Next Dimension Casement Picture | Vinyl | 0.17 | 0.12 | 1,610 |
| Vinylmax LLC — CP74 Picture Window | Vinyl | 0.17 | 0.14 | 1,603 |
| Wincore Window Company, LLC — 5400 5400S 7700 9900 Series Vinyl Fixed Window Transom | Vinyl | 0.17 | 0.14 | 1,833 |
| Lindsay Windows — Pinnacle / Healthy Double Hung | Vinyl | 0.17 | 0.16 | 1,344 |
| Sierra Pacific Windows — Vinyl Direct Set | Vinyl | 0.17 | 0.12 | 2,077 |
What other certified series does DRUTEX S.A. produce?
Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
IGLO Energy Alucover Fixed Window
U-Factor 0.14–0.20 · 10 certified options.
IGLO ENERGY Classic Fixed Window
U-Factor 0.15–0.32 · 3,527 certified options.
IGLO ENERGY Tilt and Slide Door
U-Factor 0.15–0.28 · 2,993 certified options.
MB-79N/MB-86N SI Fixed Window
U-Factor 0.15–0.32 · 2,540 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO 5 Classic Tilt Turn appear below.
How well does IGLO 5 Classic Tilt Turn by DRUTEX S.A. insulate relative to Window benchmarks?
DRUTEX S.A. IGLO 5 Classic Tilt Turn spans 1,631 certified configurations with U-Factors between 0.17 and 0.32 and SHGC values from 0.04 to 0.39. Ranked #362 of 1,352 Window families, it carries 498 Most Efficient options.
Can homeowners install IGLO 5 Classic Tilt Turn in cold Northern ENERGY STAR counties?
Yes, 666 packages satisfy Northern ENERGY STAR Version 7.0 rules in IGLO 5 Classic Tilt Turn. Pairing multi-pane insulation down to 0.17 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How does a 3x5 ft IGLO 5 Classic Tilt Turn window perform under a 40 deg F temperature drop?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 102.0 BTU/hr on IGLO 5 Classic Tilt Turn's lowest-U package (0.17), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.32 transfer proportionally more energy.
When should a buyer skip DRUTEX S.A. IGLO 5 Classic Tilt Turn and compare alternatives?
Do not specify IGLO 5 Classic Tilt Turn without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO 5 Classic Tilt Turn options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is IGLO 5 Classic Tilt Turn suitable for sunbelt cooling-dominated homes?
Across Northern, North-Central, South-Central, Southern, 948 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO 5 Classic Tilt Turn, while total line SHGC reaches 0.39 in colder packages.
How many DRUTEX S.A. IGLO 5 Classic Tilt Turn variants earn ENERGY STAR Most Efficient?
No. Exactly 498 of 1,631 configurations (30.5%) earn ENERGY STAR Most Efficient status in IGLO 5 Classic Tilt Turn; the remaining standard v7.0 options pass base zone limits only.
What federal compliance checks govern 2026 IGLO 5 Classic Tilt Turn window swaps?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 IGLO 5 Classic Tilt Turn installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
What permanent glass etch marks verify IGLO 5 Classic Tilt Turn after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line DRU-K-2 and NFRC ID DRU before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO 5 Classic Tilt Turn come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)