DRUTEX S.A. — IGLO ENERGY Classic Fixed Window · Picture Window
Positioning #136/1,352 in certified Window, DRUTEX S.A. IGLO ENERGY Classic Fixed Window pairs Vinyl frame construction with 3,527 glazing options rated between 0.04 and 0.45 SHGC across Northern, North-Central, South-Central, Southern. Across 40 certified DRUTEX S.A. product families, its thermal resistance spans 0.15 to 0.32 U-Factor and the line includes 2,023 ENERGY STAR Most Efficient packages (57.4% of line).
- Min U-Factor
- 0.15
- SHGC Range
- 0.04-0.45
- Certified Options
- 3,527
- Category Standing
- #136 of 1,352
How does DRUTEX S.A. IGLO ENERGY Classic Fixed Window compare thermally against Window peers?
DRUTEX S.A. IGLO ENERGY Classic Fixed Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows DRUTEX S.A. IGLO ENERGY Classic Fixed Window standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.
Climate coverage for DRUTEX S.A. IGLO ENERGY Classic Fixed Window spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 2,023 configurations meet ENERGY STAR Most Efficient criteria while 2,543 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2023-12-04 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 3,527 certified glazing combinations for IGLO ENERGY Classic Fixed Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 2,543 packages (1,607 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 3,247 packages (1,822 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 1,035 packages (497 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 1,140 packages (682 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| EnergyWall Window — 8650/3151 Casement | Vinyl | 0.15 | 0.14 | 2,568 |
| Polaris Windows and Doors — 8650/3151 Casement | Vinyl | 0.15 | 0.14 | 2,568 |
| EnergyWall Window — 8660 Awning | Vinyl | 0.15 | 0.14 | 2,542 |
| Polaris Windows and Doors — 8660 Awning | Vinyl | 0.15 | 0.14 | 2,542 |
| JELD-WEN, inc. — Premium Vinyl (V-4500) SH/HS Fixed Direct Set | Vinyl | 0.15 | 0.14 | 2,473 |
What other certified series does DRUTEX S.A. produce?
Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
IGLO Energy Alucover Fixed Window
U-Factor 0.14–0.20 · 10 certified options.
IGLO ENERGY Tilt and Slide Door
U-Factor 0.15–0.28 · 2,993 certified options.
MB-79N/MB-86N SI Fixed Window
U-Factor 0.15–0.32 · 2,540 certified options.
IGLO 5 Fixed Window with GU Threshold
U-Factor 0.16–0.32 · 774 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO ENERGY Classic Fixed Window appear below.
What thermal performance numbers separate DRUTEX S.A. IGLO ENERGY Classic Fixed Window from peers?
Across 3,527 tested NFRC glazing configurations, DRUTEX S.A. IGLO ENERGY Classic Fixed Window with Vinyl framing and Fixed Window (FIXD) style reaches a 0.15 minimum U-Factor and 0.04-0.45 SHGC band. It places #136 among 1,352 Window series—top 18.4%.
How does DRUTEX S.A. IGLO ENERGY Classic Fixed Window satisfy Version 7.0 Northern criteria?
Yes, 2,543 packages satisfy Northern ENERGY STAR Version 7.0 rules in IGLO ENERGY Classic Fixed Window. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How much winter heat loss does IGLO ENERGY Classic Fixed Window conduct across a 15 sq ft opening?
At U 0.15, a standard 3x5 ft (15 sq ft) IGLO ENERGY Classic Fixed Window opening transfers 90.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -42.0 BTU/hr difference.
Who should NOT choose DRUTEX S.A. IGLO ENERGY Classic Fixed Window for a residential project?
Skip IGLO ENERGY Classic Fixed Window if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO ENERGY Classic Fixed Window options exceeding U 0.22.
Can you install DRUTEX S.A. IGLO ENERGY Classic Fixed Window in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 1,140 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO ENERGY Classic Fixed Window, while total line SHGC reaches 0.45 in colder packages.
How many DRUTEX S.A. IGLO ENERGY Classic Fixed Window variants earn ENERGY STAR Most Efficient?
Not every package qualifies: 2,023 of 3,527 IGLO ENERGY Classic Fixed Window glazing builds earn Most Efficient recognition (57.4%), while other variants sit on the standard Version 7.0 tier.
Do 2026 IGLO ENERGY Classic Fixed Window installations qualify for IRS Section 25C tax credits?
Any IGLO ENERGY Classic Fixed Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
Where are NFRC and IGCC identification marks located on IGLO ENERGY Classic Fixed Window?
Match the NFRC thermal sticker for code DRU and line DRU-K-5 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO ENERGY Classic Fixed Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)