Window · Vinyl Frame NFRC DRU · Product Line DRU-K-21 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO 5 Fixed Window with GU Threshold · Picture Window

Positioning #250/1,352 in certified Window, DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold pairs Vinyl frame construction with 774 glazing options rated between 0.16 and 0.48 SHGC across Northern, North-Central, South-Central, Southern. Across 40 certified DRUTEX S.A. product families, its thermal resistance spans 0.16 to 0.32 U-Factor and the line includes 273 ENERGY STAR Most Efficient packages (35.3% of line).

Min U-Factor
0.16
SHGC Range
0.16-0.48
Certified Options
774
Category Standing
#250 of 1,352

How does DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold compare thermally against Window peers?

DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO 5 Fixed Window with GU ThresholdHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing IGLO 5 Fixed Window with GU Threshold (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO 5 Fixed Window with GU Threshold Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), IGLO 5 Fixed Window with GU Threshold reaches 0.16 on its lowest-conductivity package — #170 of 1,009 in Vinyl, tied with 100 others at 0.16, more insulating than 73.2% of Vinyl lines, top 26.8% (-0.03 vs Vinyl peers). Pairing NFRC ID DRU across multi-pane fills shifts U-Factor from 0.32 down toward 0.16.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 273 configurations meet ENERGY STAR Most Efficient criteria while 322 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2023-04-03 and v7.0 data certification on 2024-04-13. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 774 certified glazing combinations for IGLO 5 Fixed Window with GU Threshold (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 322 packages (247 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 394 packages (247 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 299 packages (69 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 522 packages (95 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold appear below.

How efficient is DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold compared with peer Window models?

Testing puts DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold at rank #250 of 1,352 Window entries with U 0.16 to 0.32 across 774 configurations. Solar heat gain ranges between 0.16 and 0.48 across Northern, North-Central, South-Central, Southern.

Does DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold qualify for the ENERGY STAR Northern Zone?

Yes. 322 packages in DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold clear ENERGY STAR v7.0 Northern targets (U <= 0.22, SHGC >= 0.17, air leakage <= 0.3 cfm/ft2). Always verify the exact glazing sticker because basic options reach U 0.32.

How do you calculate winter heat conduction for DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold?

Using NFRC DRU U-Factor 0.16, a 15 sq ft Fixed Window (FIXD) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

When should a buyer skip DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold and compare alternatives?

Do not specify IGLO 5 Fixed Window with GU Threshold without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO 5 Fixed Window with GU Threshold options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.

How many IGLO 5 Fixed Window with GU Threshold glazing packages pass Southern solar-heat rules?

Warm-climate homeowners have 522 Southern-approved options within IGLO 5 Fixed Window with GU Threshold spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

Does IGLO 5 Fixed Window with GU Threshold carry EPA Most Efficient certification across its lineup?

Within IGLO 5 Fixed Window with GU Threshold, 35.3% (273 of 774) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

What federal compliance checks govern 2026 IGLO 5 Fixed Window with GU Threshold window swaps?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 DRUTEX S.A. upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How do building inspectors verify IGLO 5 Fixed Window with GU Threshold glass specs on job sites?

Verify NFRC ID DRU and series DRU-K-21 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO 5 Fixed Window with GU Threshold come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros