Skip to main content
Window · Vinyl Frame NFRC SLC · Product Line SLC-K-5 ENERGY STAR Most Efficient Eligible

Slocomb Windows and Doors, Inc — 100/200 Series Double Hung · Double Slider

Across 8 Slocomb Windows and Doors, Inc certified families, 100/200 Series Double Hung supplies 512 Double Slider configurations starting at 0.16 U-Factor and 0.14 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.28 SHGC. Its thermal floor ranks #250 of 1,352 category entries—0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.14-0.28
Certified Options
512
Category Standing
#250 of 1,352

How does Slocomb Windows and Doors, Inc 100/200 Series Double Hung compare thermally against Window peers?

Slocomb Windows and Doors, Inc 100/200 Series Double Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 100/200 Series Double HungHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 100/200 Series Double Hung (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

100/200 Series Double Hung Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Relative to Window assemblies nationwide (median U 0.20), 100/200 Series Double Hung is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.16-0.28.

Regional qualification covers Northern, North-Central, South-Central, Southern. 196 configurations meet ENERGY STAR Most Efficient criteria while 160 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-02-08 and FENSTAR license 2023-03-23 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 512 certified glazing combinations for 100/200 Series Double Hung (NFRC SLC) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 160 packages (44 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 424 packages (119 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 372 packages (103 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 372 packages (180 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Slocomb Windows and Doors, Inc produce?

Compare other active Slocomb Windows and Doors, Inc certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Slocomb Windows and Doors, Inc 100/200 Series Double Hung appear below.

What thermal performance numbers separate Slocomb Windows and Doors, Inc 100/200 Series Double Hung from peers?

Slocomb Windows and Doors, Inc 100/200 Series Double Hung spans 512 certified configurations with U-Factors between 0.16 and 0.28 and SHGC values from 0.14 to 0.28. Ranked #250 of 1,352 Window families, it carries 196 Most Efficient options.

Can homeowners install 100/200 Series Double Hung in cold Northern ENERGY STAR counties?

Yes, 160 packages satisfy Northern ENERGY STAR Version 7.0 rules in 100/200 Series Double Hung. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How does a 3x5 ft 100/200 Series Double Hung window perform under a 40 deg F temperature drop?

At U 0.16, a standard 3x5 ft (15 sq ft) 100/200 Series Double Hung opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

What homeowner profiles are a poor match for Slocomb Windows and Doors, Inc 100/200 Series Double Hung?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 100/200 Series Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

Does 100/200 Series Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?

Warm-climate homeowners have 372 Southern-approved options within 100/200 Series Double Hung spanning SHGC down to 0.14. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.

What glazing share inside 100/200 Series Double Hung qualifies as Most Efficient?

Only 196 options out of 512 (38.3%) meet tighter Most Efficient U-Factor and SHGC thresholds in Slocomb Windows and Doors, Inc 100/200 Series Double Hung, usually requiring triple-pane or upgraded Low-E coatings.

Do 2026 100/200 Series Double Hung installations qualify for IRS Section 25C tax credits?

Tax rules ended Section 25C on December 31, 2025, shifting 2026 Slocomb Windows and Doors, Inc upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.

How can homeowners confirm delivered Slocomb Windows and Doors, Inc 100/200 Series Double Hung units match permits?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code SLC and product line SLC-K-5, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Slocomb Windows and Doors, Inc 100/200 Series Double Hung come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)