North Star Manufacturing (London) Ltd. — 1171 Casement · Casement Windows
North Star Manufacturing (London) Ltd. engineered the 1171 Casement Casement Windows line for Northern, North-Central, South-Central, Southern, certifying 293 glass-spacer combinations from 0.16 to 0.26 U-Factor and 0.13 to 0.48 SHGC. Relative to other Vinyl models tracked under NFRC NSM, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.16
- SHGC Range
- 0.13-0.48
- Certified Options
- 293
- Category Standing
- #250 of 1,352
How does North Star Manufacturing (London) Ltd. 1171 Casement compare thermally against Window peers?
North Star Manufacturing (London) Ltd. 1171 Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 11 certified North Star Manufacturing (London) Ltd. series, this Casement Windows offers a 0.10 U-Factor adjustment span between 0.26 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).
Mapping NFRC SHGC values (0.13 to 0.48) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 81 configurations meet ENERGY STAR Most Efficient criteria while 208 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-01-10 and cert timestamp 2024-12-05.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 293 certified glazing combinations for 1171 Casement (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 208 packages (36 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 199 packages (60 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 82 packages (31 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 82 packages (45 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Amsco Windows — VLS STC Serenity Awning | Vinyl | 0.16 | 0.08 | 288 |
| Amsco Windows — VLS STC Serenity Casement | Vinyl | 0.16 | 0.08 | 288 |
| Advanced Window Corp. — 6300 Casement | Vinyl | 0.16 | 0.14 | 304 |
| Crystal Window and Door Systems, Ltd. — 235 Series Casement | Vinyl | 0.16 | 0.14 | 277 |
| Vytex Corporation — 6000 Potomac Double Hung | Vinyl | 0.16 | 0.12 | 268 |
What other certified series does North Star Manufacturing (London) Ltd. produce?
Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1171 Casement appear below.
Where does North Star Manufacturing (London) Ltd. 1171 Casement stand thermally among ENERGY STAR Window lines?
North Star Manufacturing (London) Ltd. 1171 Casement spans 293 certified configurations with U-Factors between 0.16 and 0.26 and SHGC values from 0.13 to 0.48. Ranked #250 of 1,352 Window families, it carries 81 Most Efficient options.
Which glazing options in North Star Manufacturing (London) Ltd. 1171 Casement meet Northern climate limits?
Prescriptive Northern compliance covers 208 1171 Casement packages (U floor 0.16, SHGC >= 0.17). Because the complete series stretches up to U 0.26, specify the cold-climate glass code explicitly.
What conductive BTU/hr difference separates 1171 Casement from the 0.22 Northern rule?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on 1171 Casement's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.26 transfer proportionally more energy.
When should a buyer skip North Star Manufacturing (London) Ltd. 1171 Casement and compare alternatives?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 1171 Casement options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many 1171 Casement glazing packages pass Southern solar-heat rules?
Yes. 82 Southern-certified options inside North Star Manufacturing (London) Ltd. 1171 Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.48 SHGC on west-facing glass to avoid excess afternoon solar gain.
How many North Star Manufacturing (London) Ltd. 1171 Casement variants earn ENERGY STAR Most Efficient?
No. Exactly 81 of 293 configurations (27.6%) earn ENERGY STAR Most Efficient status in 1171 Casement; the remaining standard v7.0 options pass base zone limits only.
Do 2026 1171 Casement installations qualify for IRS Section 25C tax credits?
Any 1171 Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify 1171 Casement after sticker removal?
Confirm both the paper NFRC label and permanent corner glass etch match line NSM-A-11 and NFRC ID NSM before contractors discard packaging, ensuring U-Factor and air leakage <= 0.3 cfm/ft2 match local climate rules.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1171 Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)