North Star Manufacturing (London) Ltd. — 1271 Double Hung · Double Hung
Across 11 North Star Manufacturing (London) Ltd. certified families, 1271 Double Hung supplies 73 Double Hung configurations starting at 0.20 U-Factor and 0.16 SHGC for Northern, North-Central, South-Central, Southern, reaching up to 0.28 U-Factor and 0.52 SHGC. Its thermal floor ranks #671 of 1,352 category entries—matches the 0.20 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.20
- SHGC Range
- 0.16-0.52
- Certified Options
- 73
- Category Standing
- #671 of 1,352
How does North Star Manufacturing (London) Ltd. 1271 Double Hung compare thermally against Window peers?
North Star Manufacturing (London) Ltd. 1271 Double Hung achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 11 certified North Star Manufacturing (London) Ltd. series, this Double Hung offers a 0.08 U-Factor adjustment span between 0.28 entry options and 0.20 top-performing glazing. Category standing is #671/1,352 (tied with 70 others at 0.20, more insulating than 45.2% of Window lines).
Climate coverage for North Star Manufacturing (London) Ltd. 1271 Double Hung spans Northern, North-Central, South-Central, Southern, governed by Version 7.0 0.3 cfm/ft2 air leakage rules. 5 configurations meet ENERGY STAR Most Efficient criteria while 30 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.20 U-Factor yields 120.0 BTU/hr transfer (-12.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-12-06 certification.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 73 certified glazing combinations for 1271 Double Hung (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Certified | <= 0.22 | >= 0.17 | 30 packages (0 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 28 packages (1 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 38 packages (1 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 38 packages (5 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| United Window & Door Mfg., Inc. — 9600 Horizontal Slider | Vinyl | 0.20 | 0.13 | 66 |
| Soft-Lite, LLC — Elements DSL20 Slider | Vinyl | 0.20 | 0.17 | 60 |
| Soft-Lite, LLC — Imperial Elite DSL12E | Vinyl | 0.20 | 0.17 | 60 |
| Walsh Building Products — 6100 Double Slider | Vinyl | 0.20 | 0.18 | 59 |
| Thompson Creek Window Company — 7900 Double Hung | Vinyl | 0.20 | 0.17 | 88 |
What other certified series does North Star Manufacturing (London) Ltd. produce?
Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1271 Double Hung appear below.
What thermal performance numbers separate North Star Manufacturing (London) Ltd. 1271 Double Hung from peers?
Across 73 tested NFRC glazing configurations, North Star Manufacturing (London) Ltd. 1271 Double Hung with Vinyl framing and Double-Hung (VSDH) style reaches a 0.20 minimum U-Factor and 0.16-0.52 SHGC band. It places #671 among 1,352 Window series—more insulating than 45.2%.
Which glazing options in North Star Manufacturing (London) Ltd. 1271 Double Hung meet Northern climate limits?
Prescriptive Northern compliance covers 30 1271 Double Hung packages (U floor 0.20, SHGC >= 0.17). Because the complete series stretches up to U 0.28, specify the cold-climate glass code explicitly.
How do you calculate winter heat conduction for North Star Manufacturing (London) Ltd. 1271 Double Hung?
Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1271 Double Hung at U 0.20 conducts 120.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.
What are the practical limitations of specifying 1271 Double Hung?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 1271 Double Hung options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many 1271 Double Hung glazing packages pass Southern solar-heat rules?
Warm-climate homeowners have 38 Southern-approved options within 1271 Double Hung spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside 1271 Double Hung qualifies as Most Efficient?
Not every package qualifies: 5 of 73 1271 Double Hung glazing builds earn Most Efficient recognition (6.8%), while other variants sit on the standard Version 7.0 tier.
Can homeowners claim Form 5695 credits on North Star Manufacturing (London) Ltd. 1271 Double Hung in 2026?
In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1271 Double Hung retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.
How can homeowners confirm delivered North Star Manufacturing (London) Ltd. 1271 Double Hung units match permits?
Verify NFRC ID NSM and series NSM-A-17 on the removable factory sticker before installation, and document the corner IGCC laser etch with a 45-degree beam for future insulated-glass warranty claims.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1271 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)