Walsh Building Products — 6100 Double Slider · Double Slider
EPA ENERGY STAR Version 7.0 certifies 59 variants inside Walsh Building Products 6100 Double Slider, combining Vinyl frame construction with U-Factors spanning 0.20 to 0.31 and SHGC 0.18 to 0.27. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #671 of 1,352 among 1,352 Window families and posts 0.01 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.20
- SHGC Range
- 0.18-0.27
- Certified Options
- 59
- Category Standing
- #671 of 1,352
How does Walsh Building Products 6100 Double Slider compare thermally against Window peers?
Walsh Building Products 6100 Double Slider achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 6100 Double Slider spans 59 NFRC test records (WAL), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at +0.01 against the Vinyl median (0.19).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 4 configurations meet ENERGY STAR Most Efficient criteria while 14 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-10-31 and FENSTAR license 2018-07-12 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 59 certified glazing combinations for 6100 Double Slider (NFRC WAL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 14 packages (4 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 35 packages (4 Most Eff.) |
| South-Central | Certified | <= 0.28 | <= 0.23 | 28 packages (0 Most Eff.) |
| Southern | Certified | <= 0.32 | <= 0.23 | 36 packages (0 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Soft-Lite, LLC — Elements DSL20 Slider | Vinyl | 0.20 | 0.17 | 60 |
| Soft-Lite, LLC — Imperial Elite DSL12E | Vinyl | 0.20 | 0.17 | 60 |
| United Window & Door Mfg., Inc. — 9600 Horizontal Slider | Vinyl | 0.20 | 0.13 | 66 |
| North Star Manufacturing (London) Ltd. — 1272 Double Slider | Vinyl | 0.20 | 0.16 | 67 |
| Vytex Corporation — Fortis Fixed | Vinyl | 0.20 | 0.19 | 50 |
What other certified series does Walsh Building Products produce?
Compare other active Walsh Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Walsh Building Products 6100 Double Slider appear below.
How efficient is Walsh Building Products 6100 Double Slider compared with peer Window models?
Walsh Building Products 6100 Double Slider spans 59 certified configurations with U-Factors between 0.20 and 0.31 and SHGC values from 0.18 to 0.27. Ranked #671 of 1,352 Window families, it carries 4 Most Efficient options.
Is 6100 Double Slider approved for Northern Zone heating climates?
Cold-climate buyers get 14 compliant Northern packages inside 6100 Double Slider, reaching down to U 0.20. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.
What BTU/hr heat transfer results from 6100 Double Slider's 0.20 minimum U-Factor?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 120.0 BTU/hr on 6100 Double Slider's lowest-U package (0.20), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.
Who should NOT choose Walsh Building Products 6100 Double Slider for a residential project?
Do not specify 6100 Double Slider without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 6100 Double Slider options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Is 6100 Double Slider suitable for sunbelt cooling-dominated homes?
Yes, 6100 Double Slider holds 36 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.18 SHGC in cooling climates.
Are all 59 6100 Double Slider configurations ENERGY STAR Most Efficient?
Within 6100 Double Slider, 6.8% (4 of 59) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.
What federal compliance checks govern 2026 6100 Double Slider window swaps?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 6100 Double Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How do building inspectors verify 6100 Double Slider glass specs on job sites?
Match the NFRC thermal sticker for code WAL and line WAL-K-18 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Walsh Building Products 6100 Double Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)