Walsh Building Products — 6600 Casement · Casement Windows
Positioning #671/1,352 in certified Window, Walsh Building Products 6600 Casement pairs Vinyl frame construction with 24 glazing options rated between 0.16 and 0.23 SHGC across Northern, North-Central, South-Central, Southern. Across 10 certified Walsh Building Products product families, its thermal resistance spans 0.20 to 0.28 U-Factor and the line includes 7 ENERGY STAR Most Efficient packages (29.2% of line).
- Min U-Factor
- 0.20
- SHGC Range
- 0.16-0.23
- Certified Options
- 24
- Category Standing
- #671 of 1,352
How does Walsh Building Products 6600 Casement compare thermally against Window peers?
Walsh Building Products 6600 Casement achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Glazing breadth across 6600 Casement spans 24 NFRC test records (WAL), ranking #671 of 1,352 Window families (tied with 70 others at 0.20, more insulating than 45.2% of Window lines). Its 0.20 thermal floor compares at +0.01 against the Vinyl median (0.19).
Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 7 configurations meet ENERGY STAR Most Efficient criteria while 7 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2026-04-30 and FENSTAR license 2018-07-12 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 24 certified glazing combinations for 6600 Casement (NFRC WAL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 7 packages (2 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 18 packages (2 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 24 packages (2 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 24 packages (7 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Target Windows and Doors — 4550 Fixed Window | Vinyl | 0.20 | 0.19 | 24 |
| Thermo-Twin Industries, Inc. — S700/731 Welded 2-1/2 Picture Window | Vinyl | 0.20 | 0.21 | 27 |
| Vistaza Inc — Vi5 Series Casement | Vinyl | 0.20 | 0.11 | 18 |
| Vinyl Window Designs, Ltd. — 300HS Double Slider | Vinyl | 0.20 | 0.15 | 35 |
| Vinyl Window Designs, Ltd. — 365 Horizontal Slider | Vinyl | 0.20 | 0.15 | 35 |
What other certified series does Walsh Building Products produce?
Compare other active Walsh Building Products certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Walsh Building Products 6600 Casement appear below.
How efficient is Walsh Building Products 6600 Casement compared with peer Window models?
Walsh Building Products 6600 Casement spans 24 certified configurations with U-Factors between 0.20 and 0.28 and SHGC values from 0.16 to 0.23. Ranked #671 of 1,352 Window families, it carries 7 Most Efficient options.
How does Walsh Building Products 6600 Casement satisfy Version 7.0 Northern criteria?
Walsh Building Products 6600 Casement supplies 7 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.28, so inspect the NFRC order sheet before purchase.
How much winter heat loss does 6600 Casement conduct across a 15 sq ft opening?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
What are the practical limitations of specifying 6600 Casement?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 6600 Casement options exceeding U 0.22. Additionally, do not order Casement Single-Vent (CSSV) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).
Can you install Walsh Building Products 6600 Casement in Southern or South-Central zones?
Warm-climate homeowners have 24 Southern-approved options within 6600 Casement spanning SHGC down to 0.16. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
What glazing share inside 6600 Casement qualifies as Most Efficient?
Only 7 options out of 24 (29.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in Walsh Building Products 6600 Casement, usually requiring triple-pane or upgraded Low-E coatings.
Do 2026 6600 Casement installations qualify for IRS Section 25C tax credits?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do you cross-check NFRC WAL and product line WAL-K-23 on delivery?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code WAL and product line WAL-K-23, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Walsh Building Products 6600 Casement come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)