Skip to main content
Window · Vinyl Frame NFRC NSM · Product Line NSM-A-16 ENERGY STAR Most Efficient Eligible

North Star Manufacturing (London) Ltd. — 1272 Double Slider · Double Slider

North Star Manufacturing (London) Ltd. engineered the 1272 Double Slider Double Slider line for Northern, North-Central, South-Central, Southern, certifying 67 glass-spacer combinations from 0.20 to 0.28 U-Factor and 0.16 to 0.51 SHGC. Relative to other Vinyl models tracked under NFRC NSM, its minimum U-Factor is 0.01 Btu/hr·ft²·°F less insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.20
SHGC Range
0.16-0.51
Certified Options
67
Category Standing
#671 of 1,352

How does North Star Manufacturing (London) Ltd. 1272 Double Slider compare thermally against Window peers?

North Star Manufacturing (London) Ltd. 1272 Double Slider achieves a 0.20 thermal floor across Window lines, placing #671 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1272 Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.19-0.21 containing 1272 Double Slider (U 0.20).249<=0.153140.16-0.182670.19-0.21This model: U 0.203430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1272 Double Slider Cohort StandingMin U-Factor 0.20 stands at rank #671 of 1,352, outperforming 45.2% of peers.Min U-Factor 0.20Rank #671 of 1,352 (45.2% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Within the Vinyl cohort (0.19 median U-Factor), 1272 Double Slider reaches 0.20 on its lowest-conductivity package — #513 of 1,009 in Vinyl, tied with 47 others at 0.20, more insulating than 44.5% of Vinyl lines (+0.01 vs Vinyl peers). Pairing NFRC ID NSM across multi-pane fills shifts U-Factor from 0.28 down toward 0.20.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 5 configurations meet ENERGY STAR Most Efficient criteria while 20 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-12-06 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 120.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 67 certified glazing combinations for 1272 Double Slider (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Certified <= 0.22 >= 0.17 20 packages (0 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 28 packages (1 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 40 packages (1 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 40 packages (5 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.20 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
United Window & Door Mfg., Inc. — 9600 Horizontal Slider Vinyl 0.20 0.13 66
Soft-Lite, LLC — Elements DSL20 Slider Vinyl 0.20 0.17 60
Soft-Lite, LLC — Imperial Elite DSL12E Vinyl 0.20 0.17 60
Walsh Building Products — 6100 Double Slider Vinyl 0.20 0.18 59
Vytex Corporation — Fortis Fixed Vinyl 0.20 0.19 50

What other certified series does North Star Manufacturing (London) Ltd. produce?

Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1272 Double Slider appear below.

Where does North Star Manufacturing (London) Ltd. 1272 Double Slider stand thermally among ENERGY STAR Window lines?

EPA ENERGY STAR v7.0 records 67 configurations for North Star Manufacturing (London) Ltd. 1272 Double Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.20 versus a 0.20 Window median. Only 5 options earn Most Efficient status.

Can homeowners install 1272 Double Slider in cold Northern ENERGY STAR counties?

Yes, 20 packages satisfy Northern ENERGY STAR Version 7.0 rules in 1272 Double Slider. Pairing multi-pane insulation down to 0.20 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How do you calculate winter heat conduction for North Star Manufacturing (London) Ltd. 1272 Double Slider?

Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.20 U-Factor yields 120.0 BTU/hr conductive transfer (-9.1% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.

Which situations make 1272 Double Slider the wrong window or door choice?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1272 Double Slider options exceeding U 0.22. Additionally, do not order Dual-Slide Horizontal (HSXX) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Does 1272 Double Slider meet Southern hot-climate SHGC caps (<= 0.23)?

Yes, 1272 Double Slider holds 40 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.16 SHGC in cooling climates.

What glazing share inside 1272 Double Slider qualifies as Most Efficient?

EPA lists 5 Most Efficient options (7.5% share) inside North Star Manufacturing (London) Ltd. 1272 Double Slider, out of 67 total Version 7.0 entries.

Do 2026 1272 Double Slider installations qualify for IRS Section 25C tax credits?

IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 1272 Double Slider installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.

What permanent glass etch marks verify 1272 Double Slider after sticker removal?

Match the NFRC thermal sticker for code NSM and line NSM-A-16 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1272 Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros