Skip to main content
Window · Vinyl Frame NFRC NSM · Product Line NSM-A-12 ENERGY STAR Most Efficient Eligible

North Star Manufacturing (London) Ltd. — 1173 Awning · Awning (Projected)

North Star Manufacturing (London) Ltd. engineered the 1173 Awning Awning, Projected line for Northern, North-Central, South-Central, Southern, certifying 291 glass-spacer combinations from 0.16 to 0.27 U-Factor and 0.13 to 0.46 SHGC. Relative to other Vinyl models tracked under NFRC NSM, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.

Min U-Factor
0.16
SHGC Range
0.13-0.46
Certified Options
291
Category Standing
#250 of 1,352

How does North Star Manufacturing (London) Ltd. 1173 Awning compare thermally against Window peers?

North Star Manufacturing (London) Ltd. 1173 Awning achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 1173 AwningHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 1173 Awning (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

1173 Awning Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Compared across 11 certified North Star Manufacturing (London) Ltd. series, this Awning, Projected offers a 0.11 U-Factor adjustment span between 0.27 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).

Mapping NFRC SHGC values (0.13 to 0.46) against ENERGY STAR Version 7.0 targets approves Northern, North-Central, South-Central, Southern. 82 configurations meet ENERGY STAR Most Efficient criteria while 195 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-01-10 licensing and 2024-12-02 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 291 certified glazing combinations for 1173 Awning (NFRC NSM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 195 packages (36 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 187 packages (64 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 86 packages (35 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 86 packages (46 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Amsco Windows — VLS STC Serenity Awning Vinyl 0.16 0.08 288
Amsco Windows — VLS STC Serenity Casement Vinyl 0.16 0.08 288
Advanced Window Corp. — 6300 Casement Vinyl 0.16 0.14 304
Crystal Window and Door Systems, Ltd. — 235 Series Casement Vinyl 0.16 0.14 277
Vytex Corporation — 6000 Potomac Double Hung Vinyl 0.16 0.12 268

What other certified series does North Star Manufacturing (London) Ltd. produce?

Compare other active North Star Manufacturing (London) Ltd. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to North Star Manufacturing (London) Ltd. 1173 Awning appear below.

How well does 1173 Awning by North Star Manufacturing (London) Ltd. insulate relative to Window benchmarks?

North Star Manufacturing (London) Ltd. 1173 Awning spans 291 certified configurations with U-Factors between 0.16 and 0.27 and SHGC values from 0.13 to 0.46. Ranked #250 of 1,352 Window families, it carries 82 Most Efficient options.

How does North Star Manufacturing (London) Ltd. 1173 Awning satisfy Version 7.0 Northern criteria?

Cold-climate buyers get 195 compliant Northern packages inside 1173 Awning, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.27 options.

What conductive BTU/hr difference separates 1173 Awning from the 0.22 Northern rule?

Applying Q = U x Area x Delta-T on a 15 sq ft unit at 40 deg F difference (70 deg F inside vs. 30 deg F outside), 1173 Awning at U 0.16 conducts 96.0 BTU/hr against 132.0 BTU/hr at U 0.22, with air leakage capped <= 0.3 cfm/ft2.

Who should NOT choose North Star Manufacturing (London) Ltd. 1173 Awning for a residential project?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 1173 Awning options exceeding U 0.22. Additionally, do not order Projected Awning (PRAW) as a tight pocket insert in bedrooms without checking IRC Section R310 (5.7 sq ft clear area, 24 in H x 20 in W).

Is 1173 Awning suitable for sunbelt cooling-dominated homes?

Yes, 1173 Awning holds 86 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.13 SHGC in cooling climates.

What glazing share inside 1173 Awning qualifies as Most Efficient?

Only 82 options out of 291 (28.2%) meet tighter Most Efficient U-Factor and SHGC thresholds in North Star Manufacturing (London) Ltd. 1173 Awning, usually requiring triple-pane or upgraded Low-E coatings.

What federal compliance checks govern 2026 1173 Awning window swaps?

In 2026, Section 25C applies only when amending 2025 Form 5695 returns with a valid QMID; current 1173 Awning retrofits verify state DOE rebates and pre-1978 Lead RRP compliance across 15 delegated state portals.

How do you cross-check NFRC NSM and product line NSM-A-12 on delivery?

Inspectors match the temporary NFRC sticker (U 0.16-0.27, SHGC 0.13-0.46) against permit drawings for line NSM-A-12. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for North Star Manufacturing (London) Ltd. 1173 Awning come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros