Skip to main content
Window · Vinyl Frame NFRC AMS · Product Line AMS-A-60 ENERGY STAR Most Efficient Eligible

Amsco Windows — VLS STC Serenity Casement · Casement Windows

EPA ENERGY STAR Version 7.0 certifies 288 variants inside Amsco Windows VLS STC Serenity Casement, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.19 and SHGC 0.08 to 0.33. Qualifying for Northern, North-Central, South-Central, Southern, this Casement Windows family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.16
SHGC Range
0.08-0.33
Certified Options
288
Category Standing
#250 of 1,352

How does Amsco Windows VLS STC Serenity Casement compare thermally against Window peers?

Amsco Windows VLS STC Serenity Casement achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. VLS STC Serenity CasementHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing VLS STC Serenity Casement (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

VLS STC Serenity Casement Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Glazing breadth across VLS STC Serenity Casement spans 288 NFRC test records (AMS), ranking #250 of 1,352 Window families (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%). Its 0.16 thermal floor compares at -0.03 against the Vinyl median (0.19).

Regional qualification covers Northern, North-Central, South-Central, Southern. 288 configurations meet ENERGY STAR Most Efficient criteria while 112 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Registry history records EPA FENSTAR licensing on 2018-10-08 and v7.0 data certification on 2024-04-25. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.16 conducts 96.0 BTU/hr (-36.0 BTU/hr vs the 0.22 ceiling).

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 288 certified glazing combinations for VLS STC Serenity Casement (NFRC AMS) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 112 packages (56 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 288 packages (288 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 240 packages (240 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 240 packages (240 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does Amsco Windows produce?

Compare other active Amsco Windows certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Amsco Windows VLS STC Serenity Casement appear below.

What U-Factor and SHGC range does Amsco Windows VLS STC Serenity Casement achieve?

Built with Vinyl framing in Casement Single-Vent (CSSV) style, Amsco Windows VLS STC Serenity Casement offers 288 Version 7.0 configurations from U 0.16 up to 0.19, posting -0.04 against the Window median of 0.20 with 288 Most Efficient picks.

Can homeowners install VLS STC Serenity Casement in cold Northern ENERGY STAR counties?

Yes, 112 packages satisfy Northern ENERGY STAR Version 7.0 rules in VLS STC Serenity Casement. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

What conductive BTU/hr difference separates VLS STC Serenity Casement from the 0.22 Northern rule?

At U 0.16, a standard 3x5 ft (15 sq ft) VLS STC Serenity Casement opening transfers 96.0 BTU/hr across a 40 deg F gradient compared with 132.0 BTU/hr at the 0.22 Northern benchmark—a -36.0 BTU/hr difference.

When should a buyer skip Amsco Windows VLS STC Serenity Casement and compare alternatives?

Skip VLS STC Serenity Casement if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Hot Southern owners needing SHGC <= 0.23 must avoid higher-solar VLS STC Serenity Casement options near 0.33 SHGC.

Does VLS STC Serenity Casement meet Southern hot-climate SHGC caps (<= 0.23)?

Yes. 240 Southern-certified options inside Amsco Windows VLS STC Serenity Casement satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.33 SHGC on west-facing glass to avoid excess afternoon solar gain.

How many Amsco Windows VLS STC Serenity Casement variants earn ENERGY STAR Most Efficient?

EPA lists 288 Most Efficient options (100.0% share) inside Amsco Windows VLS STC Serenity Casement, out of 288 total Version 7.0 entries.

What federal compliance checks govern 2026 VLS STC Serenity Casement window swaps?

Any VLS STC Serenity Casement purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How can homeowners confirm delivered Amsco Windows VLS STC Serenity Casement units match permits?

Inspectors match the temporary NFRC sticker (U 0.16-0.19, SHGC 0.08-0.33) against permit drawings for line AMS-A-60. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Amsco Windows VLS STC Serenity Casement come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros