Skip to main content
Window · Vinyl Frame NFRC DRU · Product Line DRU-K-1 ENERGY STAR Most Efficient Eligible

DRUTEX S.A. — IGLO 5 Classic Fixed Window · Picture Window

EPA ENERGY STAR Version 7.0 certifies 1,567 variants inside DRUTEX S.A. IGLO 5 Classic Fixed Window, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.04 to 0.49. Qualifying for Northern, North-Central, South-Central, Southern, this Picture Window family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.15
SHGC Range
0.04-0.49
Certified Options
1,567
Category Standing
#136 of 1,352

How does DRUTEX S.A. IGLO 5 Classic Fixed Window compare thermally against Window peers?

DRUTEX S.A. IGLO 5 Classic Fixed Window achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. IGLO 5 Classic Fixed WindowHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin <=0.15 containing IGLO 5 Classic Fixed Window (U 0.15).249<=0.15This model: U 0.153140.16-0.182670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

IGLO 5 Classic Fixed Window Cohort StandingMin U-Factor 0.15 stands at rank #136 of 1,352, outperforming 81.6% of peers.Min U-Factor 0.15Rank #136 of 1,352 (81.6% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Thermal positioning shows DRUTEX S.A. IGLO 5 Classic Fixed Window standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 695 configurations meet ENERGY STAR Most Efficient criteria while 927 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.15 U-Factor yields 90.0 BTU/hr transfer (-42.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2023-04-03 licensing and 2023-12-04 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,567 certified glazing combinations for IGLO 5 Classic Fixed Window (NFRC DRU) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 927 packages (543 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,211 packages (590 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 466 packages (148 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 630 packages (233 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Interstate Building Materials, Inc. — 442/6802 Awning Vinyl 0.15 0.15 1,544
Interstate Building Materials, Inc. — 442/6802 Casement Vinyl 0.15 0.15 1,680
ProVia LLC — Endure Single Hung Vinyl 0.15 0.12 1,743
EnergyWall Window — 7430/3130/8630 Horizontal Slider Vinyl 0.15 0.14 1,348
Polaris Windows and Doors — 7430/3130 Horizontal Slider Vinyl 0.15 0.14 1,348

What other certified series does DRUTEX S.A. produce?

Compare other active DRUTEX S.A. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to DRUTEX S.A. IGLO 5 Classic Fixed Window appear below.

How well does IGLO 5 Classic Fixed Window by DRUTEX S.A. insulate relative to Window benchmarks?

Built with Vinyl framing in Fixed Window (FIXD) style, DRUTEX S.A. IGLO 5 Classic Fixed Window offers 1,567 Version 7.0 configurations from U 0.15 up to 0.32, posting -0.05 against the Window median of 0.20 with 695 Most Efficient picks.

Can homeowners install IGLO 5 Classic Fixed Window in cold Northern ENERGY STAR counties?

Prescriptive Northern compliance covers 927 IGLO 5 Classic Fixed Window packages (U floor 0.15, SHGC >= 0.17). Because the complete series stretches up to U 0.32, specify the cold-climate glass code explicitly.

What BTU/hr heat transfer results from IGLO 5 Classic Fixed Window's 0.15 minimum U-Factor?

Using NFRC DRU U-Factor 0.15, a 15 sq ft Fixed Window (FIXD) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).

What are the practical limitations of specifying IGLO 5 Classic Fixed Window?

Project owners who ignore local NFRC zone limits risk permit rejection. Cold-climate owners needing prescriptive U <= 0.22 should pass on IGLO 5 Classic Fixed Window options exceeding U 0.22. Verify whether your municipal code restricts Vinyl frames in wildfire or historic zones.

How many IGLO 5 Classic Fixed Window glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 630 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside DRUTEX S.A. IGLO 5 Classic Fixed Window, while total line SHGC reaches 0.49 in colder packages.

How many DRUTEX S.A. IGLO 5 Classic Fixed Window variants earn ENERGY STAR Most Efficient?

EPA lists 695 Most Efficient options (44.4% share) inside DRUTEX S.A. IGLO 5 Classic Fixed Window, out of 1,567 total Version 7.0 entries.

What 2026 federal tax credit and Lead RRP rules apply to IGLO 5 Classic Fixed Window?

Any IGLO 5 Classic Fixed Window purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC DRU and product line DRU-K-1 on delivery?

Match the NFRC thermal sticker for code DRU and line DRU-K-1 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for DRUTEX S.A. IGLO 5 Classic Fixed Window come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros