Interstate Building Materials, Inc. — 442/6802 Awning · Awning (Projected)
With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Interstate Building Materials, Inc. 442/6802 Awning spans 1,544 tested options across Northern, North-Central, South-Central, Southern up to 0.27 U-Factor. Carrying NFRC CPD code IBM, the Vinyl assembly includes 555 ENERGY STAR Most Efficient packages (35.9% of line) and offers SHGC packages between 0.15 and 0.51.
- Min U-Factor
- 0.15
- SHGC Range
- 0.15-0.51
- Certified Options
- 1,544
- Category Standing
- #136 of 1,352
How does Interstate Building Materials, Inc. 442/6802 Awning compare thermally against Window peers?
Interstate Building Materials, Inc. 442/6802 Awning achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Relative to Window assemblies nationwide (median U 0.20), 442/6802 Awning is 0.05 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median while keeping Vinyl frame construction. Selecting different glass and gas-fill packages moves thermal performance along 0.15-0.27.
Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 555 configurations meet ENERGY STAR Most Efficient criteria while 868 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-09-05 and v7.0 data certification on 2024-02-22. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,544 certified glazing combinations for 442/6802 Awning (NFRC IBM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 868 packages (276 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 1,266 packages (412 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 675 packages (261 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 675 packages (390 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| DRUTEX S.A. — IGLO 5 Classic Fixed Window | Vinyl | 0.15 | 0.04 | 1,567 |
| EnergyWall Window — 7430/3130/8630 Horizontal Slider | Vinyl | 0.15 | 0.14 | 1,348 |
| Polaris Windows and Doors — 7430/3130 Horizontal Slider | Vinyl | 0.15 | 0.14 | 1,348 |
| ProVia LLC — Endure Single Hung | Vinyl | 0.15 | 0.12 | 1,743 |
| EnergyWall Window — 7420/3120/8620 Double Hung | Vinyl | 0.15 | 0.15 | 1,340 |
What other certified series does Interstate Building Materials, Inc. produce?
Compare other active Interstate Building Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
442/6802 Direct Set CS Picture Window
U-Factor 0.14–0.27 · 1,806 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Interstate Building Materials, Inc. 442/6802 Awning appear below.
What U-Factor and SHGC range does Interstate Building Materials, Inc. 442/6802 Awning achieve?
Testing puts Interstate Building Materials, Inc. 442/6802 Awning at rank #136 of 1,352 Window entries with U 0.15 to 0.27 across 1,544 configurations. Solar heat gain ranges between 0.15 and 0.51 across Northern, North-Central, South-Central, Southern.
Does Interstate Building Materials, Inc. 442/6802 Awning qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 868 compliant Northern packages inside 442/6802 Awning, reaching down to U 0.15. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.27 options.
How do you calculate winter heat conduction for Interstate Building Materials, Inc. 442/6802 Awning?
Using NFRC IBM U-Factor 0.15, a 15 sq ft Projected Awning (PRAW) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).
Which situations make 442/6802 Awning the wrong window or door choice?
Cold-climate owners needing prescriptive U <= 0.22 should pass on 442/6802 Awning options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
Is 442/6802 Awning suitable for sunbelt cooling-dominated homes?
Yes. 675 Southern-certified options inside Interstate Building Materials, Inc. 442/6802 Awning satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.51 SHGC on west-facing glass to avoid excess afternoon solar gain.
Are all 1,544 442/6802 Awning configurations ENERGY STAR Most Efficient?
Not every package qualifies: 555 of 1,544 442/6802 Awning glazing builds earn Most Efficient recognition (35.9%), while other variants sit on the standard Version 7.0 tier.
Do 2026 442/6802 Awning installations qualify for IRS Section 25C tax credits?
Any 442/6802 Awning purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.
What permanent glass etch marks verify 442/6802 Awning after sticker removal?
Match the NFRC thermal sticker for code IBM and line IBM-K-66 directly against your county ENERGY STAR v7.0 threshold on delivery, and read the permanent corner IGCC/ANSI Z97.1 safety etch using angled flashlight illumination.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Interstate Building Materials, Inc. 442/6802 Awning come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)