Interstate Building Materials, Inc. — 440/6800 Single Hung · Single Hung
With a minimum U-Factor of 0.15—-0.05 compared against the 0.20 Window median—Interstate Building Materials, Inc. 440/6800 Single Hung spans 380 tested options across Northern, North-Central, South-Central, Southern up to 0.29 U-Factor. Carrying NFRC CPD code IBM, the Vinyl assembly includes 145 ENERGY STAR Most Efficient packages (38.2% of line) and offers SHGC packages between 0.18 and 0.50.
- Min U-Factor
- 0.15
- SHGC Range
- 0.18-0.50
- Certified Options
- 380
- Category Standing
- #136 of 1,352
How does Interstate Building Materials, Inc. 440/6800 Single Hung compare thermally against Window peers?
Interstate Building Materials, Inc. 440/6800 Single Hung achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Interstate Building Materials, Inc. 440/6800 Single Hung standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 145 configurations meet ENERGY STAR Most Efficient criteria while 218 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 90.0 BTU/hr (-31.8% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2025-05-13.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 380 certified glazing combinations for 440/6800 Single Hung (NFRC IBM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 218 packages (119 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 259 packages (105 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 177 packages (64 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 183 packages (84 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| ProVia LLC — Vinyl Awning Window | Vinyl | 0.15 | 0.06 | 397 |
| ProVia LLC — Vinyl Casement Window | Vinyl | 0.15 | 0.06 | 411 |
| Slocomb Windows and Doors, Inc — 400/500 Series Double Hung | Vinyl | 0.15 | 0.14 | 322 |
| Atrium Companies, Inc. — 8900/90/8000/1800/8900 Picture Window | Vinyl | 0.15 | 0.16 | 312 |
| Advanced Window Corp. — 6300 Large Picture Window | Vinyl | 0.15 | 0.17 | 288 |
What other certified series does Interstate Building Materials, Inc. produce?
Compare other active Interstate Building Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
442/6802 Direct Set CS Picture Window
U-Factor 0.14–0.27 · 1,806 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Interstate Building Materials, Inc. 440/6800 Single Hung appear below.
What U-Factor and SHGC range does Interstate Building Materials, Inc. 440/6800 Single Hung achieve?
Built with Vinyl framing in Single-Hung (VSSH) style, Interstate Building Materials, Inc. 440/6800 Single Hung offers 380 Version 7.0 configurations from U 0.15 up to 0.29, posting -0.05 against the Window median of 0.20 with 145 Most Efficient picks.
Is 440/6800 Single Hung approved for Northern Zone heating climates?
Interstate Building Materials, Inc. 440/6800 Single Hung supplies 218 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.29, so inspect the NFRC order sheet before purchase.
What conductive BTU/hr difference separates 440/6800 Single Hung from the 0.22 Northern rule?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.15 U-Factor yields 90.0 BTU/hr conductive transfer (-31.8% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip Interstate Building Materials, Inc. 440/6800 Single Hung and compare alternatives?
Skip 440/6800 Single Hung if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 440/6800 Single Hung options exceeding U 0.22.
Can you install Interstate Building Materials, Inc. 440/6800 Single Hung in Southern or South-Central zones?
Across Northern, North-Central, South-Central, Southern, 183 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside Interstate Building Materials, Inc. 440/6800 Single Hung, while total line SHGC reaches 0.50 in colder packages.
Are all 380 440/6800 Single Hung configurations ENERGY STAR Most Efficient?
No. Exactly 145 of 380 configurations (38.2%) earn ENERGY STAR Most Efficient status in 440/6800 Single Hung; the remaining standard v7.0 options pass base zone limits only.
What 2026 federal tax credit and Lead RRP rules apply to 440/6800 Single Hung?
IRS Section 25C ($600 windows cap) covered units placed in service through Dec 31, 2025 with a 4-character QMID code. For 2026 440/6800 Single Hung installs, check DOE HOMES/HEEHR and pre-1978 Lead RRP certification.
How can homeowners confirm delivered Interstate Building Materials, Inc. 440/6800 Single Hung units match permits?
Inspectors match the temporary NFRC sticker (U 0.15-0.29, SHGC 0.18-0.50) against permit drawings for line IBM-K-63. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Interstate Building Materials, Inc. 440/6800 Single Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)