Interstate Building Materials, Inc. — 440/6800/8800 Double Hung · Double Hung
Interstate Building Materials, Inc. engineered the 440/6800/8800 Double Hung Double Hung line for Northern, North-Central, South-Central, Southern, certifying 920 glass-spacer combinations from 0.16 to 0.30 U-Factor and 0.18 to 0.49 SHGC. Relative to other Vinyl models tracked under NFRC IBM, its minimum U-Factor is 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median.
- Min U-Factor
- 0.16
- SHGC Range
- 0.18-0.49
- Certified Options
- 920
- Category Standing
- #250 of 1,352
How does Interstate Building Materials, Inc. 440/6800/8800 Double Hung compare thermally against Window peers?
Interstate Building Materials, Inc. 440/6800/8800 Double Hung achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Compared across 15 certified Interstate Building Materials, Inc. series, this Double Hung offers a 0.14 U-Factor adjustment span between 0.30 entry options and 0.16 top-performing glazing. Category standing is #250/1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%).
Regional qualification covers Northern, North-Central, South-Central, Southern. 368 configurations meet ENERGY STAR Most Efficient criteria while 536 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Conductive modeling for a typical 3x5 ft unit (dT=40°F) puts heat loss at 96.0 BTU/hr (-27.3% vs the 132.0 BTU/hr baseline at U=0.22). Records show license timestamp 2018-09-05 and cert timestamp 2024-08-01.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 920 certified glazing combinations for 440/6800/8800 Double Hung (NFRC IBM) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 536 packages (248 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 660 packages (280 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 458 packages (158 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 470 packages (214 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| ProVia LLC — 502 / 602 Horizontal Slider | Vinyl | 0.16 | 0.05 | 957 |
| ProVia LLC — Endure / Aspect Single Hung Window | Vinyl | 0.16 | 0.06 | 866 |
| DRUTEX S.A. — IGLO 5 Fixed Window with GU Threshold | Vinyl | 0.16 | 0.16 | 774 |
| Thermo-Tech Windows — 2600 Casement w/ 2601 Sash | Vinyl | 0.16 | 0.11 | 607 |
| Gerkin Windows and Doors — 4300 Series Casement | Vinyl | 0.16 | 0.08 | 1,268 |
What other certified series does Interstate Building Materials, Inc. produce?
Compare other active Interstate Building Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
442/6802 Direct Set CS Picture Window
U-Factor 0.14–0.27 · 1,806 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Interstate Building Materials, Inc. 440/6800/8800 Double Hung appear below.
Where does Interstate Building Materials, Inc. 440/6800/8800 Double Hung stand thermally among ENERGY STAR Window lines?
Testing puts Interstate Building Materials, Inc. 440/6800/8800 Double Hung at rank #250 of 1,352 Window entries with U 0.16 to 0.30 across 920 configurations. Solar heat gain ranges between 0.18 and 0.49 across Northern, North-Central, South-Central, Southern.
Does Interstate Building Materials, Inc. 440/6800/8800 Double Hung qualify for the ENERGY STAR Northern Zone?
Cold-climate buyers get 536 compliant Northern packages inside 440/6800/8800 Double Hung, reaching down to U 0.16. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.30 options.
How do you calculate winter heat conduction for Interstate Building Materials, Inc. 440/6800/8800 Double Hung?
Over 15 sq ft of opening at a 40 deg F indoor-outdoor difference, 0.16 U-Factor yields 96.0 BTU/hr conductive transfer (-27.3% relative to 132.0 BTU/hr at U 0.22), plus <= 0.3 cfm/ft2 ASTM E283 air sealing.
When should a buyer skip Interstate Building Materials, Inc. 440/6800/8800 Double Hung and compare alternatives?
Do not specify 440/6800/8800 Double Hung without matching exact glazing codes to your county climate zone: Cold-climate owners needing prescriptive U <= 0.22 should pass on 440/6800/8800 Double Hung options exceeding U 0.22. Always confirm rough opening egress clearances for sleeping rooms.
Does 440/6800/8800 Double Hung meet Southern hot-climate SHGC caps (<= 0.23)?
Warm-climate homeowners have 470 Southern-approved options within 440/6800/8800 Double Hung spanning SHGC down to 0.18. Pair low solar gain with <= 0.3 cfm/ft2 perimeter sealing to limit summer air-conditioning runtime.
How many Interstate Building Materials, Inc. 440/6800/8800 Double Hung variants earn ENERGY STAR Most Efficient?
Not every package qualifies: 368 of 920 440/6800/8800 Double Hung glazing builds earn Most Efficient recognition (40.0%), while other variants sit on the standard Version 7.0 tier.
Can homeowners claim Form 5695 credits on Interstate Building Materials, Inc. 440/6800/8800 Double Hung in 2026?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify 440/6800/8800 Double Hung glass specs on job sites?
Inspectors match the temporary NFRC sticker (U 0.16-0.30, SHGC 0.18-0.49) against permit drawings for line IBM-K-49. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Interstate Building Materials, Inc. 440/6800/8800 Double Hung come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)