Skip to main content
Window · Vinyl Frame NFRC PRD · Product Line PRD-N-102 ENERGY STAR Most Efficient Eligible

ProVia LLC — 502 / 602 Horizontal Slider · Double Slider

EPA ENERGY STAR Version 7.0 certifies 957 variants inside ProVia LLC 502 / 602 Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.16 to 0.32 and SHGC 0.05 to 0.46. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #250 of 1,352 among 1,352 Window families and posts 0.03 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.

Min U-Factor
0.16
SHGC Range
0.05-0.46
Certified Options
957
Category Standing
#250 of 1,352

How does ProVia LLC 502 / 602 Horizontal Slider compare thermally against Window peers?

ProVia LLC 502 / 602 Horizontal Slider achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 502 / 602 Horizontal SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 502 / 602 Horizontal Slider (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

502 / 602 Horizontal Slider Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places ProVia LLC 502 / 602 Horizontal Slider at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.05-0.46 band.

Zone eligibility across EPA boundaries reaches 4 markets (Northern, North-Central, South-Central, Southern). 229 configurations meet ENERGY STAR Most Efficient criteria while 201 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Data provenance links certification 2024-10-11 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 96.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 957 certified glazing combinations for 502 / 602 Horizontal Slider (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 201 packages (66 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 463 packages (168 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 664 packages (156 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 861 packages (217 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

What other certified series does ProVia LLC produce?

Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC 502 / 602 Horizontal Slider appear below.

What U-Factor and SHGC range does ProVia LLC 502 / 602 Horizontal Slider achieve?

ProVia LLC 502 / 602 Horizontal Slider spans 957 certified configurations with U-Factors between 0.16 and 0.32 and SHGC values from 0.05 to 0.46. Ranked #250 of 1,352 Window families, it carries 229 Most Efficient options.

Can homeowners install 502 / 602 Horizontal Slider in cold Northern ENERGY STAR counties?

ProVia LLC 502 / 602 Horizontal Slider supplies 201 Northern-qualified packages meeting U <= 0.22 and air infiltration <= 0.3 cfm/ft2. Entry glazing configurations rise to U 0.32, so inspect the NFRC order sheet before purchase.

How much winter heat loss does 502 / 602 Horizontal Slider conduct across a 15 sq ft opening?

Using NFRC PRD U-Factor 0.16, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 96.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-36.0 BTU/hr margin).

Which situations make 502 / 602 Horizontal Slider the wrong window or door choice?

Skip 502 / 602 Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 502 / 602 Horizontal Slider options exceeding U 0.22.

How many 502 / 602 Horizontal Slider glazing packages pass Southern solar-heat rules?

Across Northern, North-Central, South-Central, Southern, 861 options pass EPA Southern cooling targets (<= 0.23 SHGC, <= 0.32 U-Factor) inside ProVia LLC 502 / 602 Horizontal Slider, while total line SHGC reaches 0.46 in colder packages.

What glazing share inside 502 / 602 Horizontal Slider qualifies as Most Efficient?

Not every package qualifies: 229 of 957 502 / 602 Horizontal Slider glazing builds earn Most Efficient recognition (23.9%), while other variants sit on the standard Version 7.0 tier.

How do the 25C sunset and pre-1978 Lead RRP rules affect 502 / 602 Horizontal Slider?

Any 502 / 602 Horizontal Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do you cross-check NFRC PRD and product line PRD-N-102 on delivery?

Leave the temporary NFRC label intact until inspection to confirm manufacturer code PRD and product line PRD-N-102, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for ProVia LLC 502 / 602 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros