ProVia LLC — New Aspect/Endure Picture Window · Picture Window
ProVia LLC New Aspect/Endure Picture Window is a Picture Window assembly with a Vinyl frame that reaches a minimum U-Factor of 0.13 across 404 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #36 of 1,352 in Window, its thermal floor is 0.07 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.14 to 0.58.
- Min U-Factor
- 0.13
- SHGC Range
- 0.14-0.58
- Certified Options
- 404
- Category Standing
- #36 of 1,352
How does ProVia LLC New Aspect/Endure Picture Window compare thermally against Window peers?
ProVia LLC New Aspect/Endure Picture Window achieves a 0.13 thermal floor across Window lines, placing #36 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places ProVia LLC New Aspect/Endure Picture Window at rank #36 of 1,352 (tied with 35 others at 0.13, more insulating than 94.7% of Window lines, top 5.3%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.14-0.58 band.
Regional qualification covers Northern, North-Central, South-Central, Southern. 177 configurations meet ENERGY STAR Most Efficient criteria while 281 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Data provenance links certification 2024-10-11 and FENSTAR license 2018-01-10 inside EPA Version 7.0 tables. Heat transfer computes to 78.0 BTU/hr across 15 sq ft at 40°F dT versus 132.0 BTU/hr at U=0.22.
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 404 certified glazing combinations for New Aspect/Endure Picture Window (NFRC PRD) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 281 packages (104 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 296 packages (138 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 193 packages (80 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 204 packages (119 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.13 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| Advanced Window Corp. — EU 76 Septem Fixed | Vinyl | 0.13 | 0.15 | 300 |
| North Star Manufacturing (London) Ltd. — 1071 Fixed | Vinyl | 0.13 | 0.17 | 205 |
| Slocomb Windows and Doors, Inc — 100 Series Picture Window | Vinyl | 0.13 | 0.15 | 158 |
| Harvey Industries, Inc. — Axio Direct Set Fixed Window | Vinyl | 0.13 | 0.17 | 725 |
| Vytex Corporation — 3300 Fixed | Vinyl | 0.13 | 0.15 | 78 |
What other certified series does ProVia LLC produce?
Compare other active ProVia LLC certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
Premium Fiberglass Entry Door
U-Factor 0.09–0.28 · 23,856 certified options.
Fiberglass Entry Door
U-Factor 0.12–0.28 · 38,144 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to ProVia LLC New Aspect/Endure Picture Window appear below.
What U-Factor and SHGC range does ProVia LLC New Aspect/Endure Picture Window achieve?
Testing puts ProVia LLC New Aspect/Endure Picture Window at rank #36 of 1,352 Window entries with U 0.13 to 0.31 across 404 configurations. Solar heat gain ranges between 0.14 and 0.58 across Northern, North-Central, South-Central, Southern.
Is New Aspect/Endure Picture Window approved for Northern Zone heating climates?
Cold-climate buyers get 281 compliant Northern packages inside New Aspect/Endure Picture Window, reaching down to U 0.13. Confirm the selected spacer and Low-E package stays at or below 0.22 rather than higher 0.31 options.
How do you calculate winter heat conduction for ProVia LLC New Aspect/Endure Picture Window?
Conductive heat flow equals U x 15 sq ft x 40 deg F = 78.0 BTU/hr on New Aspect/Endure Picture Window's lowest-U package (0.13), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.31 transfer proportionally more energy.
Who should NOT choose ProVia LLC New Aspect/Endure Picture Window for a residential project?
Cold-climate owners needing prescriptive U <= 0.22 should pass on New Aspect/Endure Picture Window options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.
How many New Aspect/Endure Picture Window glazing packages pass Southern solar-heat rules?
Yes, New Aspect/Endure Picture Window holds 204 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.14 SHGC in cooling climates.
How many ProVia LLC New Aspect/Endure Picture Window variants earn ENERGY STAR Most Efficient?
EPA lists 177 Most Efficient options (43.8% share) inside ProVia LLC New Aspect/Endure Picture Window, out of 404 total Version 7.0 entries.
Can homeowners claim Form 5695 credits on ProVia LLC New Aspect/Endure Picture Window in 2026?
No Section 25C federal tax credit applies to 2026 installs because 25C expired December 31, 2025; use state DOE HOMES or HEEHR rebates instead. Pre-1978 homes still mandate EPA or state-authorized Lead RRP firms.
How do building inspectors verify New Aspect/Endure Picture Window glass specs on job sites?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code PRD and product line PRD-N-112, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for ProVia LLC New Aspect/Endure Picture Window come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)