Skip to main content
Window · Vinyl Frame NFRC IBM · Product Line IBM-K-52 ENERGY STAR Most Efficient Eligible

Interstate Building Materials, Inc. — 440/6800/8800 Double Slider · Double Slider

Interstate Building Materials, Inc. 440/6800/8800 Double Slider is a Double Slider assembly with a Vinyl frame that reaches a minimum U-Factor of 0.16 across 1,522 certified glazing configurations covering Northern, North-Central, South-Central, Southern. Ranked #250 of 1,352 in Window, its thermal floor is 0.04 Btu/hr·ft²·°F more insulating than the 0.20 Btu/hr·ft²·°F median, while Solar Heat Gain Coefficient ratings run from 0.18 to 0.48.

Min U-Factor
0.16
SHGC Range
0.18-0.48
Certified Options
1,522
Category Standing
#250 of 1,352

How does Interstate Building Materials, Inc. 440/6800/8800 Double Slider compare thermally against Window peers?

Interstate Building Materials, Inc. 440/6800/8800 Double Slider achieves a 0.16 thermal floor across Window lines, placing #250 of 1,352 against the 0.20 category median.

Cohort Minimum U-Factor Distribution

Window U-Factor Distribution vs. 440/6800/8800 Double SliderHistogram of 1,352 ENERGY STAR v7.0 Window lines grouped by minimum U-Factor, highlighting bin 0.16-0.18 containing 440/6800/8800 Double Slider (U 0.16).249<=0.153140.16-0.18This model: U 0.162670.19-0.213430.22-0.241460.25-0.27310.28-0.3020.31-0.3500.36-0.420>0.42Category median min U: 0.20 (lower U = better thermal resistance)

Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).

Thermal Standing & NFRC Anatomy

440/6800/8800 Double Slider Cohort StandingMin U-Factor 0.16 stands at rank #250 of 1,352, outperforming 73.3% of peers.Min U-Factor 0.16Rank #250 of 1,352 (73.3% standing)Highest UNational/Cohort Median (50th)Lowest U (#1)
NFRC Window Thermal Cross-Section and 45-Degree Glass Etch InspectionArchitectural cutaway of a multi-pane insulated glass unit showing conductive U-factor heat loss, solar heat gain coefficient (SHGC), 0.3 cfm/ft2 perimeter air seal, and 45-degree corner laser stamp inspection.EXTERIOR CLIMATEINTERIOR ROOM (70 deg F)U-Factor (Heat Loss)SHGC (Solar Gain)Air Leakage Seal: ≤ 0.3 cfm/ft2 (ASTM E283)IGCC / IGMA Corner Stamp CheckIGCC45 deg flashlightHold dark paperbehind outer glassto read plant/yr ID

NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).

Category benchmarking against 1,352 ENERGY STAR v7.0 Window lines places Interstate Building Materials, Inc. 440/6800/8800 Double Slider at rank #250 of 1,352 (tied with 111 others at 0.16, more insulating than 73.3% of Window lines, top 26.7%; cohort median 0.20). Moving between double-pane low-emissivity and argon/triple assemblies shifts SHGC across the 0.18-0.48 band.

Evaluating climate compliance across Northern, North-Central, South-Central, Southern separates cold-weather U <= 0.22 options from cooling-dominated glazing. 596 configurations meet ENERGY STAR Most Efficient criteria while 848 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).

Under a 40°F indoor-outdoor winter gradient on 15 sq ft of glass, 0.16 U-Factor yields 96.0 BTU/hr transfer (-36.0 BTU/hr vs the 0.22 ceiling). Manufacturer filing reflects 2018-09-05 licensing and 2024-06-20 certification.

Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?

Compare the 1,522 certified glazing combinations for 440/6800/8800 Double Slider (NFRC IBM) against EPA ENERGY STAR v7.0 regional limits.

Climate Zone Qualification Status EPA Max U-Factor EPA SHGC Rule Certified Package Count
Northern Most Efficient <= 0.22 >= 0.17 848 packages (332 Most Eff.)
North-Central Most Efficient <= 0.25 <= 0.40 1,108 packages (484 Most Eff.)
South-Central Most Efficient <= 0.28 <= 0.23 838 packages (256 Most Eff.)
Southern Most Efficient <= 0.32 <= 0.23 866 packages (344 Most Eff.)

Which competing Window series sit closest on U-Factor?

Inspect nearby Window competitors clustered closest to 0.16 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.

Peer Series Frame Material Min U-Factor Min SHGC Options
Windsor Windows and Doors — Next Dimension Picture Vinyl 0.16 0.12 1,539
DRUTEX S.A. — IGLO Energy Fixed Window Plus COMBI Threshold Vinyl 0.16 0.15 1,443
Windsor Windows and Doors — Next Dimension Radius Vinyl 0.16 0.13 1,382
ProVia LLC — Vinyl Double Hung Window Vinyl 0.16 0.05 1,307
Amsco Windows — VLS STC Serenity Picture Window Vinyl 0.16 0.12 1,272

What other certified series does Interstate Building Materials, Inc. produce?

Compare other active Interstate Building Materials, Inc. certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.

What thermal, air-leakage, and egress questions affect installation?

Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Interstate Building Materials, Inc. 440/6800/8800 Double Slider appear below.

What U-Factor and SHGC range does Interstate Building Materials, Inc. 440/6800/8800 Double Slider achieve?

EPA ENERGY STAR v7.0 records 1,522 configurations for Interstate Building Materials, Inc. 440/6800/8800 Double Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.16 versus a 0.20 Window median. Only 596 options earn Most Efficient status.

Can homeowners install 440/6800/8800 Double Slider in cold Northern ENERGY STAR counties?

Yes, 848 packages satisfy Northern ENERGY STAR Version 7.0 rules in 440/6800/8800 Double Slider. Pairing multi-pane insulation down to 0.16 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.

How much winter heat loss does 440/6800/8800 Double Slider conduct across a 15 sq ft opening?

Conductive heat flow equals U x 15 sq ft x 40 deg F = 96.0 BTU/hr on 440/6800/8800 Double Slider's lowest-U package (0.16), versus 132.0 BTU/hr at U = 0.22. Higher-U options up to 0.29 transfer proportionally more energy.

What homeowner profiles are a poor match for Interstate Building Materials, Inc. 440/6800/8800 Double Slider?

Cold-climate owners needing prescriptive U <= 0.22 should pass on 440/6800/8800 Double Slider options exceeding U 0.22. Buyers in pre-1978 homes also need Lead-Safe RRP certified contractors rather than uncertified general crews when disturbing painted window stops.

What Southern ENERGY STAR v7.0 options exist in 440/6800/8800 Double Slider?

Yes, 440/6800/8800 Double Slider holds 866 Southern ENERGY STAR listings meeting SHGC <= 0.23 and U <= 0.32. Specify tint/spectrally selective Low-E glass near 0.18 SHGC in cooling climates.

Does 440/6800/8800 Double Slider carry EPA Most Efficient certification across its lineup?

Within 440/6800/8800 Double Slider, 39.2% (596 of 1,522) hold Most Efficient designation. Ask your dealer specifically for the Most Efficient SKU if local utility rebates require it.

How do the 25C sunset and pre-1978 Lead RRP rules affect 440/6800/8800 Double Slider?

Any 440/6800/8800 Double Slider purchase installed in 2026 falls outside expired IRS 25C rules and transitions to state DOE weatherization rebates. Paid installers disturbing pre-1978 exterior paint must follow EPA 40 CFR 745 Lead RRP rules.

How do building inspectors verify 440/6800/8800 Double Slider glass specs on job sites?

Inspectors match the temporary NFRC sticker (U 0.16-0.29, SHGC 0.18-0.48) against permit drawings for line IBM-K-52. Permanent laser corner etches document IGCC certification and tempered safety glass compliance.

Which official federal and state sources back this page?

NFRC thermal benchmarks and eligibility metrics for Interstate Building Materials, Inc. 440/6800/8800 Double Slider come directly from EPA ENERGY STAR ProductFinder records.

  1. ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
  2. ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
  3. Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
  4. Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)

High-Demand Window & Exterior Cost Metros