Polaris Windows and Doors — 7430/3130 Horizontal Slider · Double Slider
EPA ENERGY STAR Version 7.0 certifies 1,348 variants inside Polaris Windows and Doors 7430/3130 Horizontal Slider, combining Vinyl frame construction with U-Factors spanning 0.15 to 0.32 and SHGC 0.14 to 0.50. Qualifying for Northern, North-Central, South-Central, Southern, this Double Slider family places #136 of 1,352 among 1,352 Window families and posts 0.04 Btu/hr·ft²·°F more insulating than the 0.19 Btu/hr·ft²·°F median among Vinyl peers.
- Min U-Factor
- 0.15
- SHGC Range
- 0.14-0.50
- Certified Options
- 1,348
- Category Standing
- #136 of 1,352
How does Polaris Windows and Doors 7430/3130 Horizontal Slider compare thermally against Window peers?
Polaris Windows and Doors 7430/3130 Horizontal Slider achieves a 0.15 thermal floor across Window lines, placing #136 of 1,352 against the 0.20 category median.
Cohort Minimum U-Factor Distribution
Minimum U-Factor across 1,352 EPA-certified Window lines (category median: 0.20).
Thermal Standing & NFRC Anatomy
NFRC performance separates conductive heat loss (U-Factor), solar radiation (SHGC), and weatherstrip air infiltration (<= 0.3 cfm/ft2).
Thermal positioning shows Polaris Windows and Doors 7430/3130 Horizontal Slider standing at #136 of 1,352 certified Window product series, tied with 113 others at 0.15, more insulating than 81.6% of Window lines, top 18.4%. Comparing Vinyl profiles alone (median 0.19) shows -0.04 before selecting Low-E tiers.
Regional qualification covers Northern, North-Central, South-Central, Southern. 578 configurations meet ENERGY STAR Most Efficient criteria while 711 combinations satisfy Northern thermal limits (U <= 0.22, SHGC >= 0.17).
Registry history records EPA FENSTAR licensing on 2018-01-10 and v7.0 data certification on 2025-02-20. Over a standard 15 sq ft rough opening at 40°F winter delta, min U 0.15 conducts 90.0 BTU/hr (-42.0 BTU/hr vs the 0.22 ceiling).
Which ENERGY STAR Version 7.0 climate zones qualify for this assembly?
Compare the 1,348 certified glazing combinations for 7430/3130 Horizontal Slider (NFRC POL) against EPA ENERGY STAR v7.0 regional limits.
| Climate Zone | Qualification Status | EPA Max U-Factor | EPA SHGC Rule | Certified Package Count |
|---|---|---|---|---|
| Northern | Most Efficient | <= 0.22 | >= 0.17 | 711 packages (241 Most Eff.) |
| North-Central | Most Efficient | <= 0.25 | <= 0.40 | 956 packages (474 Most Eff.) |
| South-Central | Most Efficient | <= 0.28 | <= 0.23 | 888 packages (397 Most Eff.) |
| Southern | Most Efficient | <= 0.32 | <= 0.23 | 907 packages (501 Most Eff.) |
Which competing Window series sit closest on U-Factor?
Inspect nearby Window competitors clustered closest to 0.15 U-Factor within ENERGY STAR Version 7.0 ProductFinder filings.
| Peer Series | Frame Material | Min U-Factor | Min SHGC | Options |
|---|---|---|---|---|
| EnergyWall Window — 7430/3130/8630 Horizontal Slider | Vinyl | 0.15 | 0.14 | 1,348 |
| EnergyWall Window — 7420/3120/8620 Double Hung | Vinyl | 0.15 | 0.15 | 1,340 |
| Euroline Windows Inc. — Energeto Neo-76 Tilt and Turn Window | Vinyl | 0.15 | 0.13 | 1,299 |
| Interstate Building Materials, Inc. — 442/6802 Awning | Vinyl | 0.15 | 0.15 | 1,544 |
| DRUTEX S.A. — IGLO 5 Classic Fixed Window | Vinyl | 0.15 | 0.04 | 1,567 |
What other certified series does Polaris Windows and Doors produce?
Compare other active Polaris Windows and Doors certified product families to check whether sister series carry tighter frame sightlines or lower U-Factor floors.
8605/3205 Casement Picture Window
U-Factor 0.13–0.29 · 3,472 certified options.
8480/7480/3080 Patio Door
U-Factor 0.16–0.28 · 3,179 certified options.
What thermal, air-leakage, and egress questions affect installation?
Installation, thermal zone compliance, air infiltration, and glass verification answers tailored to Polaris Windows and Doors 7430/3130 Horizontal Slider appear below.
What thermal performance numbers separate Polaris Windows and Doors 7430/3130 Horizontal Slider from peers?
EPA ENERGY STAR v7.0 records 1,348 configurations for Polaris Windows and Doors 7430/3130 Horizontal Slider covering Northern, North-Central, South-Central, Southern, dropping down to U 0.15 versus a 0.20 Window median. Only 578 options earn Most Efficient status.
Is 7430/3130 Horizontal Slider approved for Northern Zone heating climates?
Yes, 711 packages satisfy Northern ENERGY STAR Version 7.0 rules in 7430/3130 Horizontal Slider. Pairing multi-pane insulation down to 0.15 U-Factor with <= 0.3 cfm/ft2 sealing cuts winter heat loss.
How much winter heat loss does 7430/3130 Horizontal Slider conduct across a 15 sq ft opening?
Using NFRC POL U-Factor 0.15, a 15 sq ft Dual-Slide Horizontal (HSXX) assembly conducts 90.0 BTU/hr at 40 deg F delta versus 132.0 BTU/hr at the Northern 0.22 limit (-42.0 BTU/hr margin).
Which situations make 7430/3130 Horizontal Slider the wrong window or door choice?
Skip 7430/3130 Horizontal Slider if local historic preservation boards prohibit Vinyl profiles or if coastal wind-borne debris ordinances mandate ASTM E1996 laminated impact glass. Cold-climate owners needing prescriptive U <= 0.22 should pass on 7430/3130 Horizontal Slider options exceeding U 0.22.
Can you install Polaris Windows and Doors 7430/3130 Horizontal Slider in Southern or South-Central zones?
Yes. 907 Southern-certified options inside Polaris Windows and Doors 7430/3130 Horizontal Slider satisfy SHGC <= 0.23 and U <= 0.32 caps. Reject configurations near 0.50 SHGC on west-facing glass to avoid excess afternoon solar gain.
What glazing share inside 7430/3130 Horizontal Slider qualifies as Most Efficient?
Not every package qualifies: 578 of 1,348 7430/3130 Horizontal Slider glazing builds earn Most Efficient recognition (42.9%), while other variants sit on the standard Version 7.0 tier.
What 2026 federal tax credit and Lead RRP rules apply to 7430/3130 Horizontal Slider?
Tax rules ended Section 25C on December 31, 2025, shifting 2026 Polaris Windows and Doors upgrades to DOE HOMES (up to $8,000) and HEEHR ($14,000 cap). Homes built prior to 1978 require Lead-Safe certified installers.
How do building inspectors verify 7430/3130 Horizontal Slider glass specs on job sites?
Leave the temporary NFRC label intact until inspection to confirm manufacturer code POL and product line POL-M-43, then shine a 45-degree flashlight over dark paper to verify the permanent IGCC/IGMA corner glass stamp.
Which official federal and state sources back this page?
NFRC thermal benchmarks and eligibility metrics for Polaris Windows and Doors 7430/3130 Horizontal Slider come directly from EPA ENERGY STAR ProductFinder records.
- ENERGY STAR Certified Residential Windows, Doors, and Skylights Product Finder — U.S. EPA ENERGY STAR, Version 7.0 Live Catalog (checked 2026-11-23)
- ENERGY STAR Program Requirements for Residential Windows, Doors, and Skylights — Eligibility Criteria Version 7.0 — U.S. EPA ENERGY STAR, Version 7.0 (Effective Oct 23, 2023) (checked 2026-11-23)
- Understanding the NFRC Energy Performance Label (U-Factor, SHGC, VT, Air Leakage) — National Fenestration Rating Council (NFRC), 2026 (checked 2026-11-23)
- Energy Efficient Home Improvement Credit (Section 25C — Placed-in-Service Deadline Dec 31, 2025) — Internal Revenue Service (IRS), 2025/2026 Statutory Update (checked 2026-11-23)